Dust control is a permit condition, not an accessory
6 t/h at 1.25 MPa is the working point for a paper plant in Konya, Turkey, where the mill is near housing and the permit requires a bag filter. The unit was selected on that operating pattern rather than on a catalogue rating, and the difference shows in how it holds pressure on the worst shift of the week.
Solid-fuel boilers emit fly ash, and the limit in most jurisdictions is written as milligrams per normal cubic metre, with a visible-emission test on top. A multi-cyclone removes the coarse fraction and is cheap, but it passes the fine particles that make the plume. A bag filter or a wet scrubber takes the rest, and the choice depends on the fuel, the flue temperature and the water available on site.
Numbers that decide the design
At 6 t/h and 1.25 MPa the unit absorbs about 4.3 MW. On paper waste at roughly 79% efficiency, full-load demand is about 1 kg/h. The figures are stated at the site’s conditions, because ambient temperature, altitude and fuel analysis all move them.
| Item | Value |
|---|---|
| Rated output | 6 t/h |
| Pressure / temperature | 1.25 MPa |
| Fuel | paper waste |
| Full-load fuel demand | 1 kg/h |
| Thermal efficiency | about 79% |
What to watch on site
The filter is only as good as its maintenance. A torn bag shows up as a rise in differential pressure or stack opacity, and a bypass damper left open after maintenance is the classic cause of a failed stack test. Ash from the filter has to go somewhere: a covered bin, a manifest and a disposal route agreed before the first run.
Site note: the mill is near housing and the permit requires a bag filter. The operators log header pressure and stack temperature every two hours, which is enough to see fouling and load drift before either becomes a shutdown.
Why it matters
Dust control is a permit condition, not an accessory is not a detail to settle after the order. It decides the shell size, the burner, the feedwater train and the maintenance calendar, and it is cheaper to get right in the specification than in the boiler house.
Equipment used in this kind of plant: dzl chain grate biomass boiler and water treatment system. The industry side is covered in this solution page, and project cases show comparable installations.
Background reading: external reference on steam and process heat.
Questions plant engineers ask
Cyclone or bag filter?
A cyclone is enough for coarse ash and lenient limits. Bag filters are needed where the limit is below about 50 mg/Nm3 or the plume is visible.
Why does a bag filter fail a stack test?
Usually a torn bag, a leaking gasket or a bypass left open. Differential pressure and opacity trends catch all three early.
Related note: 4 t/h Gas steam boiler in Philippines: Where the fuel actually goes



