700-7000 kW (60-600 ×10⁴ kcal/h)
YGL Biomass Thermal Oil Heater, 700-7000 kW
Horizontal chain-grate biomass thermal oil heater, 700-7000 kW, liquid phase to 320 °C at under 1.0 MPa, with coil banks matched t...
View detailsThe SZL4-1.25-T delivers 4 t/h of steam at 1.25 MPa and 194 °C from biomass pellets, wood chips, rice husk or palm kernel shell. Assembled chain-grate, two-drum water-tube design rated at 88% efficiency on LHV.

The SZL4-1.25-T is a 4 t/h unit in the SZL biomass steam boiler series. It is an assembled chain-grate, two-drum water-tube boiler designed for solid biomass fuels: biomass pellets, wood chips, rice husk and palm kernel shell. Rated steam output is 4 t/h at 1.25 MPa and 194 °C, with thermal efficiency of 88% on a lower heating value (LHV) basis.
At 4 t/h, this unit fits process steam loads that run continuously but do not justify a larger, site-erected boiler. Typical duty profiles include food and beverage processing, feed milling, textile finishing, small-to-mid laundries, and district or campus heating plants with a steam distribution network. The capacity also suits plants that want a single boiler sized to their base steam demand with modest headroom, rather than a large unit running at low output.
The rated fuel consumption is 682 kg/h. This figure is calculated, not measured, from the rated output and the stated efficiency:
Because the figure is tied to a stated fuel and efficiency, actual consumption will move with fuel calorific value, moisture and ash content. Wood chips and rice husk, for example, have different LHV and bulk behaviour from pellets, so the 682 kg/h figure should be read as the rated-output reference point for pellets at 4,000 kcal/kg.
A 4 t/h chain-grate unit is typically operated across a moderate turn-down range rather than at a fixed point. At this size, part-load operation is managed through grate speed, air distribution and feed rate, with the water-tube circuit responding to load changes through the two-drum arrangement. Efficiency at part load depends on excess air control and fuel bed consistency; the 88% figure applies at rated output on the stated fuel basis. Buyers with strongly variable steam demand should discuss their load profile, since sustained low-load running affects fuel bed stability and efficiency.
The SZL4-1.25-T is supplied as an assembled chain-grate, two-drum water-tube boiler. In general terms, the installation envelope must accommodate the boiler body, the chain grate and fuel feed, the draft system, the steam and feedwater connections, and access for grate and tube maintenance. Space is also needed for fuel storage and handling, ash removal, and water treatment equipment. Site-specific layout, foundations and clearances should be confirmed against the manufacturer’s general arrangement drawings for the project.
Water-tube boilers at this pressure require disciplined feedwater and boiler water treatment. The two-drum water-tube circuit has smaller internal passages than a fire-tube design, so scale and carryover control matter for tube life and steam quality. A treatment programme matched to the local raw water — softening and, where required, deaeration — should be in place before commissioning, with routine blowdown and monitoring.
The unit is supplied with combustion and feedwater controls appropriate to a chain-grate boiler: grate speed, forced and induced draft, fuel feed and drum water level. Control configuration for a given project is agreed at order stage to match the plant’s steam demand pattern and integration requirements.
Choosing 4 t/h rather than the next size down avoids running a smaller unit flat out with no reserve for peaks. Choosing it rather than the next size up avoids a boiler that spends most of its life at low load, where fuel bed behaviour and efficiency are harder to hold. The 4 t/h rating sits at the point where a single assembled chain-grate unit covers a steady process load with sensible headroom.
| Parameter | Value |
|---|---|
| Model | SZL4-1.25-T |
| Capacity | 4 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | To be confirmed per project |
| Fuel | Biomass pellets, wood chips, rice husk, palm kernel shell |
| Fuel consumption at rated output | 682 kg/h (biomass pellets at 4,000 kcal/kg, 88% efficiency) |
| Efficiency | 88% (LHV basis) |
| Burner/control | Chain-grate combustion; combustion and feedwater controls per project |
| Application | Process steam and heating |
The unit is rated at 4 t/h of steam at 1.25 MPa and 194 °C. It suits steady process steam or heating loads at that scale; buyers with strongly variable demand should share their load profile so part-load operation can be assessed.
No. The 682 kg/h figure is calculated for biomass pellets at 4,000 kcal/kg with 88% efficiency on LHV. Wood chips, rice husk and palm kernel shell differ in calorific value, moisture and ash, so consumption will differ from the pellet reference figure.
As a two-drum water-tube boiler, it requires feedwater and boiler water treatment suited to the local raw water, typically including softening and, where required, deaeration, plus routine blowdown and monitoring to protect the tube circuit and maintain steam quality.
| Model | SZL4-1.25-T |
|---|---|
| Capacity | 4 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | To be confirmed per project |
| Fuel | Biomass pellets, wood chips, rice husk, palm kernel shell |
| Fuel consumption at rated output | 682 kg/h (biomass pellets at 4,000 kcal/kg, 88% efficiency) |
| Efficiency | 88% (LHV basis) |
| Burner/control | Chain-grate combustion; combustion and feedwater controls per project |
| Application | Process steam and heating |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.