
6-100 t/h
SZS Water-Tube Gas/Oil Steam Boiler, 6-100 t/h
Membrane-wall water-tube steam boiler with staged combustion and FGR, 6-100 t/h at up to 2.5 MPa and 98% efficiency with heat reco...
View details2.8 MW thermal oil heater at 280 °C on natural gas, commissioned in 2023 in Monterrey, Mexico: one reactor closes its valve without warning and the coil flow dropped below the minimum.

2.8 MW at 280 °C, fired on natural gas, was commissioned in 2023 for a chemical plant in Monterrey. One reactor closes its valve without warning and the coil flow dropped below the minimum. The fix was a YY(Q)W series unit selected on the measured load, not on the nominal process rating.
The constraint was not the boiler alone but the fuel and water going into it. The previous unit was replaced twice without anyone changing the fuel handling. The site runs one extended shift and the steam demand is set by batch equipment rather than by a continuous process, so the load curve has a sharp morning peak and a long plateau.
| Item | Value |
|---|---|
| Model | YY(Q)W series, 2.8 MW |
| Working pressure | 280 °C |
| Fuel | natural gas |
| Full-load fuel demand | 315 Nm3/h |
| Thermal efficiency | about 90% |
| Heat input at rating | 2.8 MW |
The scope covered the pressure vessel, burner, feedwater pump set, controls and the safety interlock chain. Site work was limited to foundations, flue, water and fuel connections, because the unit arrived assembled and tested.
One reactor closes its valve without warning and the coil flow dropped below the minimum. The measured load profile showed the peak was short and repeatable, so the answer was to make the boiler follow it without losing stability, and to remove the manual compensation the operators had invented. Commissioning included a 72-hour run at the real pattern, with the combustion curve trimmed at four firing rates.
After handover, a minimum-flow bypass with an automatic control valve protects the coil; the plant has had no coking incident since. The plant logs header pressure and stack temperature every two hours, which is enough to catch fouling and load drift before either becomes a shutdown.
Comparable installations are listed under project cases, and the equipment is described on the product page. Fuel and water treatment choices for this kind of site are covered in the industry solutions section.
External links open the publisher’s website and are provided for background reading.
The measured fifteen-minute peak was covered by 2.8 MW with a 10% margin. A larger unit would have run below its stable minimum for most of the day, which costs more in part-load losses than it saves in peak headroom.
Seven days on site for this size, including hydraulic test, boil-out, steam blowing, safety-valve setting and a 72-hour run at the plant's real load pattern.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.