View detailsTwo 2 t/h gas thermal oil heaters, about 1.4 MW each, hold 280 °C for bitumen heating in Sudan, where a 6.4 MPa steam plant was the alternative.

Thermal oil heaters are still ordered in tonnes per hour in many markets, a convention inherited from steam: one tonne per hour is roughly 0.7 MW. Two 2 t/h heaters therefore give 2.8 MW of oil-side heat. Each circulates some 76 m³/h at 280 °C supply and 250 °C return — a 30 K drop that carries 1.4 MW at the oil’s specific heat of about 2.6 kJ/kg·K and a density near 850 kg/m³.
The site heats bitumen for asphalt production. Storage tanks are held at 150-180 °C, so the loop must deliver well above the bitumen temperature.
The 280 °C outlet is above the bitumen temperature so the oil can give up heat across a tank coil with a usable approach. A 280/250 loop holds a 70-100 K approach, which keeps the coil surface small and the bitumen from coking on it.
Steam at 280 °C would sit near 6.4 MPa. Pipe, valves, the heater shell and the feed system would all be high-pressure equipment, and the site would need a water treatment plant, a deaerator and a licensed operator. A liquid-phase oil loop at 280 °C runs at 0.8 MPa, uses standard pipe, has no traps, no blowdown and no water treatment, and cannot freeze because there is no water in it. For an export site with a small operating team, that difference decides the order.
Each burner is set up for the gas analysis supplied at order, because a gas-fired unit going to a site without a pipeline network is configured for the fuel it will actually burn — vaporised LPG, an LPG/air mixture or associated gas — and the gas train, orifice and combustion head follow from that analysis rather than from a generic natural gas figure.
The burners carry margin on fan capacity. At 45-50 °C ambient the air density is about 0.9 of its 20 °C value, so a burner selected on standard conditions would be short of air at full fire. Dust is the other factor: the intake has a coarse filter, and the gas side fouls faster than the oil side, showing first as a rising stack temperature.
Each heater has its own circulating pump with a standby, a minimum-flow bypass, and a closed expansion tank at the highest point with a nitrogen blanket to keep hot oil from oxidising. The loop is filled through a filter, and the oil is circulated cold with the vents open before the burner is lit, to drive off moisture. Warm-up is limited to 50 K/h.
Oil life is set by film temperature, not bulk temperature. The coils are sized so tube velocity stays above 1.5 m/s at full flow, which keeps the wall film inside the oil supplier’s limit at 280 °C. The plant samples oil every 500 hours for viscosity, flash point and insolubles; a falling flash point means light ends are forming through cracking.
The temperature difference across the heater is the best instrument on the plant: a widening drop at constant flow means the coil is fouling on the oil side or the burner is down on output. Stack temperature does the same job for the gas side. Neither replaces the annual internal inspection, but both give months of warning. The safety chain — flow switch, high outlet temperature, low expansion tank level and flame failure — is proved before each season, because a thermal oil heater has no water to absorb a loss of flow, and a stopped pump will coke a coil within minutes.
| Item | Value |
|---|---|
| Nominal rating | 2 t/h, about 1.4 MW |
| Oil supply / return | 280 / 250 °C |
| Circulating flow | about 76 m³/h |
| Loop pressure | 0.8 MPa |
| Warm-up rate | 50 K/h maximum |
External links open the publisher’s website and are provided for background reading.
It is the steam-equivalent convention still used in China: 1 t/h is about 0.7 MW, so a 2 t/h heater is roughly 1.4 MW. Always confirm the MW figure, since oil ratings are sometimes quoted in kcal/h instead.
Saturated steam at 280 °C needs about 6.4 MPa, which brings high-pressure pipework, a deaerator, water treatment and a licensed operator. A liquid-phase oil loop does the same duty at 0.8 MPa with no traps and no blowdown.
Film temperature at the tube wall, not the bulk oil temperature. Keeping tube velocity above 1.5 m/s at full flow holds the film inside the oil's limit; running the loop at low flow cokes the coil even at a correct outlet temperature.