6 t/h
6 t/h Coal Steam Boiler DZL6-1.25-AII
The DZL6-1.25-AII is a 6 t/h single-drum chain-grate coal steam boiler delivering 1.25 MPa steam at 194 °C. It burns bituminous co...
View detailsThe DZL10-1.25-AII is a 10 t/h single-drum chain-grate coal steam boiler producing 1.25 MPa steam at 194 °C, with threaded smoke tubes and 84% efficiency (LHV basis).

The DZL10-1.25-AII is the 10 t/h model of the DZL series: a single-drum, chain-grate steam boiler with threaded smoke tubes, designed around coal firing. It delivers 10 t/h of steam at 1.25 MPa and 194 °C, and is rated at 84% efficiency on a lower heating value (LHV) basis.
At 10 t/h, this unit sits in the middle of the industrial steam range. It suits plants whose steam demand runs continuously through the working day but does not justify a larger, multi-boiler house: process heating, drying, and general plant steam where the load profile is steady rather than sharply peaking. Where demand is intermittent or highly variable, a smaller unit or a modular arrangement may fit better; where demand is continuous and above this level, the next size up in the series is the natural step.
The boiler fires bituminous coal, anthracite, and lignite. The rated fuel consumption is 1429 kg/h at rated output, and that figure follows directly from the brief’s stated basis: bituminous coal at 5,000 kcal/kg and 84% efficiency (LHV). In other words, the figure is the coal input needed to hold 10 t/h of output when the fuel matches that calorific value and the boiler runs at its rated efficiency. Coal with a different calorific value will shift the mass rate accordingly; the 1429 kg/h figure should be read as the rated-output reference point, not a constant for every coal.
A 10 t/h chain-grate unit is large enough that part-load operation is a normal condition rather than an exception. The chain grate and the threaded smoke tubes are intended to keep combustion and heat transfer stable as load falls, but efficiency at part load will not equal the 84% rated figure. Buyers planning sustained operation well below rated output should treat the rated efficiency as an upper reference and expect the boiler to be selected and controlled with the actual load profile in mind.
As a single-drum chain-grate boiler at this capacity, the unit requires a boiler house with room for the pressure part, the grate and its coal feed, the flue gas path, and access for maintenance and tube work. The brief supplies no dimensions or weights, so the installation envelope must be confirmed against the manufacturer’s general arrangement drawing for the specific configuration before civil works are planned. Allow for coal handling on the feed side and ash removal on the discharge side.
Feedwater quality is a design input, not an afterthought. The brief does not state a feedwater temperature, so that value must be fixed with the manufacturer for the actual installation. In all cases, the feedwater and boiler water should be treated to the program specified for this boiler, with particular attention to scale and carryover control, since the steam outlet is specified at 194 °C and the pressure part is a single drum with threaded smoke tubes.
The brief does not specify a burner or control package for this model; the control arrangement should be confirmed with the manufacturer as part of the order. What the brief does establish is the firing basis: a chain grate with coal feed, which sets the control task around grate speed, coal feed, and the steam pressure and temperature targets of 1.25 MPa and 194 °C.
Choosing the 10 t/h model rather than the next size down keeps margin for steady plant demand without running the boiler flat out; choosing it rather than the next size up avoids carrying capacity the plant does not use, which matters for part-load efficiency and for the space and handling equipment the boiler house must accommodate. The right answer depends on the measured load profile, not on the nameplate alone.
| Parameter | Value |
|---|---|
| Model | DZL10-1.25-AII |
| Capacity | 10 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | To be confirmed with manufacturer |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 1429 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain grate; control package to be confirmed |
| Application | Industrial process steam and heating |
It assumes bituminous coal at 5,000 kcal/kg and 84% efficiency on an LHV basis, at rated output. Coal with a different calorific value will change the mass rate.
Yes. Part-load operation is a normal condition at this size, but efficiency at part load will be below the 84% rated figure, so the load profile should guide selection.
The brief does not specify either. Both should be confirmed with the manufacturer for the specific installation before the boiler house is designed.
| Model | DZL10-1.25-AII |
|---|---|
| Capacity | 10 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | To be confirmed with manufacturer |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 1429 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain grate; control package to be confirmed |
| Application | Industrial process steam and heating |