Capacity & Cost guide Industrial boiler manufacturer since 1965 Taikang, Zhoukou, Henan, China
Boiler Auxiliaries

Boiler Economizer and Air Preheater

Finned tube economizers and tubular air preheaters for fire-tube, water-tube and thermal oil systems, with cold-end protection against acid dew point.

Technical parameters
Boiler capacity served1 t/h2 t/h4 t/h6 t/h10 t/h
Economizer heating surface11.8 m²22.6 m²32.2 m²56.2 m²132.2 m²
Feedwater in / out20 / 90 °C20 / 78 °C20 / 90 °C20 / 76 °C20 / 104 °C
Exit gas temperature150 °C148 °C146 °C145 °C140 °C
Gas-side resistance250 Pa280 Pa300 Pa320 Pa350 Pa
Cold-end materialND steelND steelND steelND steelND steel

Request a quotation for this boiler

Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.

Or email [email protected] directly.

Partners

Become a Yuanda Boiler agent

We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.

Apply as an agent
WhatsApp [email protected]
Call WhatsApp Email Get a quote