Steam in a brewery is not one load but three very different ones. Wort boiling is a large, predictable thermal duty tied to evaporation rate; CIP is a spiky, short-duration demand driven by vessel size and water temperature rise; packaging needs dry, clean steam at modest flow but high quality. Sizing a boiler on total annual steam consumption will undersize the plant, because the peaks — not the average — set the capacity. This article walks through the numbers for each duty so you can build a realistic load profile before requesting a proposal.
Wort boiling: evaporation rate sets the duty
Wort boiling sterilises, isomerises hop acids and drives off unwanted volatiles. The key design figure is evaporation intensity, usually expressed as a percentage of the wort volume per hour. Typical ranges are 6–10 %/h for modern internal or external calandria kettles, with 8 %/h a common design point. For a 20 hL (2 m³) cast-out volume at 8 %/h, you evaporate about 160 L/h of water.
The steam duty follows from the latent heat of water at boiling pressure. At atmospheric boiling, latent heat is roughly 2,257 kJ/kg; allowing for a small sensible component and kettle efficiency, use about 2,700 kJ per kg of water evaporated as a working figure. That gives:
- 160 kg/h evaporated × 2,700 kJ/kg ≈ 432,000 kJ/h ≈ 120 kW thermal.
- At 6 bar(g) saturated steam (latent heat ≈ 2,085 kJ/kg), that is roughly 60 kg/h of steam for the kettle alone.
Boil duration matters for energy, not peak: a 60-minute boil at this rate consumes about 60 kg of steam per brew. Multiply by brews per day and days per week to get the weekly wort-boiling energy. If you run high-gravity brewing or a whirlpool with extended stand, adjust the evaporation percentage accordingly. The capacity and cost guide explains how to convert these duties into a boiler rating with margin.
CIP: short, sharp and often simultaneous
Clean-in-place is where breweries get caught out. A CIP cycle heats a volume of water or caustic to 70–80 °C, holds it, then rinses. The heating step is the peak. Consider a 5,000 L CIP set heating from 15 °C to 80 °C in 45 minutes:
- Energy = 5,000 kg × 4.18 kJ/kg·K × 65 K ≈ 1,359,000 kJ.
- Over 45 minutes (2,700 s): ≈ 503 kW thermal.
- At 6 bar(g), that is roughly 870 kg/h of steam — for one CIP set.
If two CIP sets run together, or a CIP overlaps with wort boiling, the instantaneous demand can exceed the sum of the individual averages. This is why a load profile by 15-minute interval is more useful than a daily total. Insulated CIP tanks and a larger storage volume reduce the heating rate and therefore the peak; a buffer hot-water tank can shave the boiler size considerably.
Packaging: steam quality, not quantity
Packaging lines use steam for pasteurisation, bottle and keg washing, and sometimes for shrink tunnels. Flows are modest — often 100–400 kg/h per line — but the steam must be dry and clean. Wet steam carries droplets that can contaminate product contact surfaces and cause erratic temperature control. Specify a dryness fraction of at least 0.95 at the point of use, with proper trapping, insulation and separator placement. For direct steam injection into product or water, use culinary-grade steam generated from treated feedwater with appropriate carryover control; discuss water treatment and steam purity requirements with your supplier rather than assuming potable feedwater is sufficient.
Worked load profile
The table below shows a simplified brewery load profile. Assumptions: 20 hL brewhouse, 8 %/h evaporation, 6 bar(g) saturated steam, CIP heating as calculated above, packaging lines at steady flow. Values are indicative and must be replaced with your measured data.
| Duty | Duration | Steam flow (kg/h) | Notes |
|---|---|---|---|
| Wort kettle | 60 min | 60 | 20 hL at 8 %/h evaporation |
| CIP set 1 | 45 min heat | 870 | 5,000 L, 15→80 °C |
| CIP set 2 (if simultaneous) | 45 min heat | 870 | Overlap with set 1 doubles peak |
| Packaging line | Continuous | 150–400 | Per line, dry steam required |
| Hot water / mash | Batch | 100–200 | Depends on infusion ratio |
Note the CIP peak dominates. A boiler sized on the kettle alone would be badly undersized; one sized on the sum of all duties without diversity would be oversized and inefficient at part load. Apply a diversity factor to simultaneous CIP and packaging, and keep a margin of 10–15 % for fouling and future expansion.
Sizing checklist
- List every steam user with its design steam flow and duration.
- Build a 15-minute interval load profile for a typical and a worst-case day.
- Identify overlapping CIP and brewhouse duties.
- Confirm steam pressure at each user, not just at the boiler.
- Check steam quality requirements for packaging and any direct injection.
- Allow for feedwater temperature and condensate return percentage.
- Decide whether a buffer hot-water tank can reduce the peak.
- Review part-load efficiency, since breweries rarely run at full load.
For equipment options across these duties, see our product range.
What drives cost
Cost is driven by peak steam flow, operating pressure, fuel type, feedwater quality and the degree of automation — not by brewery size alone. A plant with a high CIP peak but low average demand may be better served by a smaller boiler plus buffer storage than by a large boiler running at low load. Steam quality requirements for packaging may add treatment and separator costs. We do not quote prices in articles; the capacity and cost guide sets out the factors.
What to send us for a proposal
- Brewhouse size (hL cast-out), evaporation rate and boil duration.
- CIP set volumes, target temperatures and heating times.
- Packaging line count and steam flow per line, with quality requirements.
- Required steam pressure and feedwater temperature.
- Condensate return percentage and water treatment details.
- Fuel available and any emissions limits.
- Site constraints: boiler room dimensions, flue route, electrical supply.
With these figures we can build a load profile and propose a boiler and steam system matched to your peaks rather than your averages.