View detailsA 6 t/h chain-grate boiler burning coal and paper waste supplies drying steam at a paper mill in Lahore, with a bag filter and an air preheater for the high-ash fuel.

The mill in Lahore makes test liner and fluting from waste paper. Steam dries the sheet on two cylinder machines and heats the size press, and the load is 4-5 t/h with a 5.5 t/h peak. The boiler is a 6 t/h SZL assembled water-tube unit at 1.25 MPa, firing a mix of local coal and the mill’s own paper rejects.
Local coal is the constraint: 20-25% ash, 4-6% moisture and an LHV around 16-17 MJ/kg. The furnace is sized for the ash, and the boiler has a two-stage air preheater to keep the bed stable when the coal is wet.
The mill runs about 80% coal and 20% shredded rejects. Paper rejects burn fast and light, so they are fed with the coal rather than separately. The chain grate runs at 4-6 m/h with a bed of 150-180 mm, and the arch is set for the coal’s volatile content.
At 6 t/h the boiler absorbs about 4.2 MW. On 16.5 MJ/kg coal at 80% efficiency the fuel rate is about 1.15 t/h, and the mill’s coal yard holds 20 days of stock.
| Item | Value |
|---|---|
| Rated evaporation | 6 t/h |
| Pressure | 1.25 MPa |
| Fuel | coal with paper rejects |
| Coal LHV | 16-17 MJ/kg |
| Fuel rate at rating | about 1.15 t/h |
| Dust control | multi-cyclone plus bag filter |
In the monsoon the coal arrives wetter, and without preheated air the furnace temperature drops and the mill loses capacity. The air preheater lifts combustion air to about 110 °C, which keeps the bed stable at 20% moisture. The cold-end elements are enamel-coated because the coal’s sulphur makes the dew point aggressive.
The bag filter runs at 130-150 °C and uses pulse-jet cleaning. The mill’s permit requires dust below 50 mg/Nm3, and the filter is sized with a 20% margin for the wet season.
The mill’s water is hard and the softener is shared with the paper machine. Boiler water is held at 2,500 ppm with automatic blowdown, and the feedwater is deaerated. The boiler runs continuously through the week with a Sunday shutdown for grate cleaning.
The boiler has run two years and holds 1.2 MPa through the drying section. Coal consumption is about 27 t a day at the mill’s average load, and the mill estimates a 30% saving against the fuel oil it burned before. Grate bars are replaced annually and the bag filter’s bags every two years.
External links open the publisher’s website and are provided for background reading.
Yes, with a larger furnace and grate and an ash handling system sized for the load. The furnace volume, not the grate area, is usually the limit.
Wet coal lowers furnace temperature and slows ignition. Air at 110 C restores bed stability and recovers some of the loss.
About 1.1-1.2 t/h at rating on 16-17 MJ/kg coal, or roughly 27 t a day at the mill's average load.