0.06-0.7 MW (10-90 ×10⁴ kcal/h)
CLHS Vertical Atmospheric Hot Water Boiler
Bottom-fired vertical fire-tube hot water boiler, 0.06-0.7 MW at atmospheric pressure, 85/65 C, for small heating and pool loads.
View detailsThe SZS20-1.6-Q is a 20 t/h D-type double-drum water-tube boiler producing steam at 1.6 MPa and 204 °C. It achieves 95% efficiency (LHV) on natural gas, LPG, light diesel, or heavy fuel oil, with a rated fuel consumption of 1486 Nm³/h on natural gas.

The SZS20-1.6-Q delivers 20 tonnes of steam per hour at 1.6 MPa and 204 °C, making it suitable for medium-to-large industrial processes that require a steady, high-volume steam supply. Typical applications include food processing, chemical manufacturing, textile operations, paper mills, and district heating plants where steam demand consistently falls in the 15–20 t/h range. The D-type double-drum water-tube design with membrane walls provides robust performance for continuous duty, and the multi-fuel capability (natural gas, LPG, light diesel, heavy fuel oil) offers flexibility in regions with variable fuel availability or pricing.
The rated fuel consumption of 1486 Nm³/h is based on natural gas operation at the boiler’s rated output and 95% efficiency on a lower heating value (LHV) basis. This figure is calculated from the steam output, pressure, and feedwater temperature, assuming a typical feedwater temperature (see specifications). The calculation accounts for the energy required to convert feedwater to steam at 204 °C and 1.6 MPa, divided by the boiler efficiency. For other fuels, the volumetric or mass flow rate will differ according to their respective heating values and densities; consult the burner manufacturer’s data for precise figures.
At 20 t/h capacity, the boiler exhibits good part-load performance due to its water-tube design and modulating burner. The burner turndown ratio (typically 5:1 for gas, 3:1 for oil) allows stable operation down to 20–30% of rated capacity, which helps match variable steam demand without frequent cycling. Efficiency at part load remains relatively high, though slightly lower than at full load due to reduced heat transfer effectiveness and increased relative heat losses. The membrane wall construction ensures uniform thermal expansion and minimizes stress during load changes, contributing to reliable operation across the load range.
The SZS20-1.6-Q is a packaged, shop-assembled boiler designed for indoor installation. It requires a dedicated boiler room with sufficient floor area for the unit, burner, and auxiliary equipment (feedwater pumps, economizer, air preheater, and control panel). The D-type layout means the boiler has a relatively compact footprint compared to other water-tube designs, but adequate clearance must be provided for tube inspection and maintenance. Foundation requirements are typical for a boiler of this capacity, and the unit is delivered with lifting lugs for positioning. No specific dimensions are provided here; refer to the general arrangement drawing for detailed space planning.
Proper water treatment is critical for the longevity and efficiency of any water-tube boiler, and the SZS20-1.6-Q is no exception. Feedwater should be softened and deaerated to prevent scale formation and oxygen corrosion. The recommended water quality limits for this pressure (1.6 MPa) typically include: total hardness <0.03 mmol/L, dissolved oxygen <0.05 mg/L, pH 10.5–12.0 at 25 °C, and iron <0.1 mg/L. A continuous blowdown system is essential to control dissolved solids, and regular water testing should be performed to maintain these parameters. Inadequate water treatment can lead to tube overheating, scale-induced efficiency loss, and premature failure.
The boiler is equipped with a modern burner management system (BMS) and a programmable logic controller (PLC) that monitors and regulates all critical operating parameters. The control system includes automatic ignition, flame monitoring, fuel/air ratio control, and safety interlocks for low water level, high pressure, and flame failure. A touchscreen interface provides real-time data on steam pressure, temperature, fuel consumption, and efficiency. The system supports remote monitoring and can be integrated into a plant-wide SCADA network. For multi-boiler installations, lead-lag control is available to optimize efficiency and equalize runtime.
Choosing a 20 t/h boiler is often a balance between capital cost, operating flexibility, and redundancy. A smaller unit (e.g., 15 t/h) might have lower initial cost but could lack capacity during peak demand or require frequent operation at maximum load, reducing efficiency and increasing wear. A larger unit (e.g., 25 t/h) offers more headroom but may operate at low load for extended periods, leading to higher specific fuel consumption and potential cycling issues. The 20 t/h size is ideal for plants with a base steam demand around 14–16 t/h and peaks up to 20 t/h, providing a comfortable margin without excessive oversizing. It also allows for future expansion without immediate additional capital outlay.
| Model | SZS20-1.6-Q |
|---|---|
| Capacity | 20 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | 104 °C (typical, based on 20 °C feedwater with economizer) |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 1486 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with PLC and BMS |
| Application | Industrial process steam, district heating |
The SZS20-1.6-Q produces 20 tonnes of steam per hour at a pressure of 1.6 MPa and a temperature of 204 °C.
It can burn natural gas, LPG, light diesel, or heavy fuel oil. On natural gas at rated output and 95% efficiency, fuel consumption is 1486 Nm³/h.
Feedwater should be softened and deaerated to meet typical limits for 1.6 MPa boilers: total hardness
| Model | SZS20-1.6-Q |
|---|---|
| Capacity | 20 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | 104 °C (typical) |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 1486 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with PLC and BMS |
| Application | Industrial process steam, district heating |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.