10 t/h
10 t/h Coal Steam Boiler DZL10-1.25-AII
The DZL10-1.25-AII is a 10 t/h single-drum chain-grate coal steam boiler producing 1.25 MPa steam at 194 °C, with threaded smoke t...
View detailsThe DZL6-1.25-AII is a 6 t/h single-drum chain-grate coal steam boiler delivering 1.25 MPa steam at 194 °C. It burns bituminous coal, anthracite or lignite at 84% efficiency (LHV), with threaded smoke tubes and a coal-focused furnace design.

The DZL6-1.25-AII is a single-drum, chain-grate coal-fired steam boiler in the DZL series. It produces 6 t/h of steam at 1.25 MPa and 194 °C. The design is coal-focused: a travelling chain grate feeds a furnace sized for solid fuel, and threaded smoke tubes improve gas-side heat transfer through the convection bank. The unit accepts bituminous coal, anthracite and lignite.
At 6 t/h, this boiler fits plants whose steam demand sits in the middle of the small-to-medium industrial band. Typical matches include:
The 1.25 MPa rating and 194 °C steam temperature cover saturated-steam process duty; the capacity leaves headroom for peaks without the part-load penalty of a much larger unit.
The rated fuel consumption is 857 kg/h. This figure follows from the steam output and the stated coal basis:
In other words, the 857 kg/h applies to bituminous coal at 5,000 kcal/kg burned at 84% efficiency. Anthracite and lignite differ in calorific value and burn characteristics, so actual consumption shifts with the fuel actually fired. The figure is a design reference at rated output, not a guarantee for every coal.
A 6 t/h chain-grate unit is large enough to hold stable combustion when demand falls, provided the grate speed and air supply are trimmed together. Below rated output, excess air tends to rise and efficiency drops; the threaded smoke tubes help maintain heat pickup across the convection section as gas velocity falls. For sustained operation well under half load, plan firing practice around shorter, steadier runs rather than long low-fire periods, which raise unburned-carbon losses on the grate.
The DZL6-1.25-AII is a packaged-style single-drum boiler with an integral chain grate. The installation envelope must account for:
Exact dimensions and weights are set by the manufacturer’s general arrangement drawing for the specific build; they are not stated here.
Feedwater quality governs tube life in any coal-fired boiler, and this unit is no exception. Threaded smoke tubes and the convection bank are vulnerable to scale, which raises metal temperature and cuts efficiency. A feedwater treatment programme should control hardness, alkalinity, dissolved oxygen and dissolved solids, with regular blowdown to hold boiler water within limits. Softening plus deaeration is the usual baseline; the exact regime depends on the raw water supply.
The boiler is supplied with combustion and feedwater controls matched to chain-grate operation: grate speed, forced and induced draft, feedwater regulation and steam pressure control. Instrumentation typically covers steam pressure, water level, flue-gas temperature and draft. Control scope and automation level are confirmed at order, since they vary with the plant’s requirements.
Choose the 6 t/h model when demand clusters around 4–6 t/h with modest peaks. The next size down leaves little margin for peak loads; the next size up adds capital cost and runs at lower part-load efficiency when demand is modest. The DZL6-1.25-AII sits at the point where a single coal-fired unit covers process demand without oversizing.
| Parameter | Value |
|---|---|
| Model | DZL6-1.25-AII |
| Capacity | 6 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified in brief |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 857 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate stoker; combustion and feedwater controls |
| Application | Process steam for food, textile, chemical and building-material plants |
It delivers 6 t/h of steam at 1.25 MPa and 194 °C, fired on a chain grate with bituminous coal, anthracite or lignite.
857 kg/h, based on bituminous coal at 5,000 kcal/kg and 84% efficiency (LHV basis). Consumption changes with the coal actually fired.
Yes. Chain-grate units hold stable combustion at reduced output when grate speed and air supply are trimmed together; efficiency falls as load drops, so long low-fire periods should be avoided.
| Model | DZL6-1.25-AII |
|---|---|
| Capacity | 6 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified in brief |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 857 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate stoker; combustion and feedwater controls |
| Application | Process steam for food, textile, chemical and building-material plants |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.