20 t/h Coal Steam Boiler DZL20-1.25-AII
The DZL20-1.25-AII is a 20 t/h single-drum chain-grate coal steam boiler producing steam at 1.25 MPa and 194 °C. It fires bitumino...
View detailsThe DZL2-1.25-AII is a 2 t/h single-drum chain-grate steam boiler rated at 1.25 MPa and 194 °C, firing bituminous coal, anthracite or lignite at 84% efficiency (LHV basis), with threaded smoke tubes and a coal-focused furnace design.

The DZL2-1.25-AII is the 2 t/h model of the DZL coal steam boiler series. It is a single-drum, chain-grate unit with threaded smoke tubes, rated at 1.25 MPa and 194 °C saturated steam temperature. The design is coal-focused: the grate, furnace and gas path are arranged around the combustion behaviour of bituminous coal, anthracite and lignite rather than around a multi-fuel compromise.
At 2 t/h the unit covers continuous process steam demand in the small-to-mid industrial range: food and beverage processing, textile finishing, small chemical and pharmaceutical plants, building-material curing, laundry and garment operations, and district or campus heating plants where steam is the distribution medium. It also suits plants that run one boiler as base load with a second as standby, or that need a steam source matched to a single production line rather than a whole site.
The rated fuel consumption is 286 kg/h. This figure follows from the rated output and the stated efficiency, and it is tied to a defined coal quality: bituminous coal at 5,000 kcal/kg fired at 84% efficiency on an LHV basis. The calculation is a straightforward heat balance — the coal input required to deliver 2 t/h of steam at the rated pressure and temperature, divided by the efficiency. Buyers should read the number as a reference point, not a guarantee for every coal: a lower calorific value raises the mass rate proportionally, and anthracite or lignite will shift both the rate and the combustion behaviour. The figure is stated with its basis precisely so that it can be recalculated for the coal actually available.
A 2 t/h chain-grate boiler is typically sized with margin above average demand, so much of its running life is spent below rated output. At this capacity the chain grate and the threaded smoke-tube bank retain stable combustion at reduced load, and the single-drum arrangement keeps water-level response manageable during swings. Efficiency at part load depends heavily on excess-air control and on how the grate speed and coal bed are managed; the 84% figure applies at rated output. Plants with strongly varying demand should plan steam accumulation or sequencing rather than expect rated efficiency at all loads.
The unit is a packaged single-drum boiler with an integral chain grate, supplied as a shop-assembled pressure part with site work limited to foundations, ducting, piping and electrical connection. The installation envelope must provide for coal feed and ash removal at the grate ends, flue-gas ducting to the stack or economiser, blowdown and feedwater connections, and the operating and maintenance access required around the drum, grate and tube bank. General arrangement drawings should be obtained for the specific site; this page states no dimensions.
As with any steam boiler at 1.25 MPa, feedwater and boiler water quality must be controlled to protect the drum, tubes and threaded smoke-tube surfaces from scale and corrosion. A treatment programme matched to the site’s raw water — softening plus internal conditioning, with regular blowdown — is a prerequisite for reliable operation and for holding efficiency over time. Scale on the gas-side-heated tubes directly erodes the efficiency figure and should be treated as an operating limit, not a maintenance afterthought.
The unit is supplied with combustion and feedwater control appropriate to a chain-grate boiler: grate speed and forced-draft adjustment to follow steam demand, feedwater regulation to hold drum level, and the standard pressure and safety interlocks. Control scope and instrumentation should be confirmed against the project specification at order stage.
Below 2 t/h, a smaller unit leaves little margin for demand peaks and for the efficiency penalty of frequent cycling. Above 2 t/h, the next size up carries more capital cost, a larger installation envelope and a minimum stable load that may exceed average demand. The 2 t/h model sits where a single coal-fired chain-grate unit can carry a plant’s base steam load with useful headroom, without the part-load penalty of an oversized boiler.
| Parameter | Value |
|---|---|
| Model | DZL2-1.25-AII |
| Capacity | 2 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not stated in brief |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 286 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate firing; combustion and feedwater controls per project specification |
| Application | Process steam and heating in small-to-mid industrial plants |
It assumes bituminous coal at 5,000 kcal/kg fired at 84% efficiency on an LHV basis, at rated output. With a lower calorific value the mass rate rises proportionally; anthracite and lignite also change combustion behaviour and should be assessed for the specific supply.
Yes, within limits. The chain grate and threaded smoke-tube bank hold stable combustion at reduced load, but the 84% efficiency applies at rated output. For strongly varying demand, plan steam accumulation or boiler sequencing rather than relying on rated efficiency at all loads.
Feedwater and boiler water quality must be controlled to prevent scale and corrosion in the drum and tubes. A programme matched to the site's raw water — typically softening plus internal conditioning with regular blowdown — is required to protect the pressure parts and hold efficiency.
| Model | DZL2-1.25-AII |
|---|---|
| Capacity | 2 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | 20 °C (105 °C with deaerator) |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 286 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate firing; combustion and feedwater controls per project specification |
| Application | Process steam and heating in small-to-mid industrial plants |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.