0.5-20 Gcal/h (0.58-23.3 MW)
Coal-Fired Hot Air Furnace, 0.5-20 Gcal/h
Indirect coal-fired hot air furnace, 0.5-20 Gcal/h, delivering 150-600 °C clean air for grain, timber, brick and gypsum drying wit...
View detailsThe DZL20-1.25-AII is a 20 t/h single-drum chain-grate coal steam boiler producing steam at 1.25 MPa and 194 °C. It fires bituminous coal, anthracite or lignite at 84% efficiency (LHV), consuming 2857 kg/h at rated output.

The DZL20-1.25-AII is a single-drum chain-grate steam boiler rated at 20 t/h, with a design pressure of 1.25 MPa and a steam temperature of 194 °C. It is built around coal firing, accepting bituminous coal, anthracite and lignite, and uses threaded smoke tubes to promote heat transfer in the convective pass. Rated thermal efficiency is 84% on a lower heating value (LHV) basis.
At 20 t/h, this unit sits in the mid-to-large industrial range. It suits plants whose steam demand is steady and substantial rather than intermittent: process industries running continuous shifts, larger district or campus steam networks, and factories where several smaller boilers would otherwise be paralleled. The single 20 t/h drum simplifies operation and housekeeping compared with a battery of small units, while leaving headroom for demand swings without the capital and space profile of a larger single boiler.
The published fuel consumption of 2857 kg/h applies at rated output and is tied to a defined coal specification: bituminous coal at 5,000 kcal/kg and 84% efficiency (LHV basis). The calculation follows the standard heat-balance route — the heat required to raise 20 t/h of feedwater to steam at 1.25 MPa and 194 °C is divided by the coal’s calorific value and the boiler efficiency. Because the figure is specification-bound, actual consumption will move with coal calorific value, moisture and ash content, excess air, and load. Anthracite and lignite are accepted fuels but will not reproduce 2857 kg/h at the same output; consumption must be recalculated for their calorific values.
Chain-grate boilers of this size generally operate most efficiently near their design point, and the 84% figure should be read as a rated-output value. At reduced load, excess air tends to rise and grate and draft settings need adjustment to hold combustion quality, so efficiency falls away from rating. The 20 t/h platform has enough grate area and furnace volume that turndown is practical for normal process swings, but sustained operation at low fractions of rating is not where the unit performs best. Where the load profile is genuinely variable, planning the operating band and grate speed settings around the expected duty is worthwhile.
The DZL20-1.25-AII is a field-erected or site-assembled package of substantial scale, not a small packaged unit. Planning should account for the boiler body and drum, the chain-grate assembly and ash handling below the grate, the coal feed arrangement, draft equipment, and the flue-gas path to the stack. Access is needed on all sides for grate maintenance, tube cleaning and inspection, plus space for coal delivery and ash removal. Structural loads, foundation design and clearances must be confirmed against the manufacturer’s general arrangement drawings for the specific project; no dimensions or weights are stated here.
As with any 20 t/h steam boiler at 1.25 MPa, feedwater and boiler water quality must be managed to protect the drum, threaded smoke tubes and steam circuit from scale, corrosion and carryover. A properly sized and operated external treatment train plus in-boiler chemical control is essential; the specific limits and treatment scheme should follow the applicable water-quality standard for this pressure and the site’s raw-water analysis.
Control scope covers combustion and draft regulation, feedwater control to hold drum level, and the safety interlocks expected on a boiler of this rating. The exact burner and control package is project-specific and should be confirmed at order; the specification row below reflects that the control arrangement is configured per installation rather than fixed by model number.
Choosing 20 t/h rather than the next size down avoids running a smaller unit flat out with little reserve for peaks, and avoids the efficiency penalty of pushing a unit beyond its design band. Choosing it rather than the next size up keeps capital, footprint and part-load behaviour aligned with a demand that does not justify a larger drum and grate. The DZL20-1.25-AII is the right fit when continuous steam demand clusters around this rating and coal is the intended fuel.
| Parameter | Value |
|---|---|
| Model | DZL20-1.25-AII |
| Capacity | 20 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified in brief |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 2857 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate firing; control package configured per project |
| Application | Continuous industrial process steam and district/campus steam networks |
The 2857 kg/h figure is defined for bituminous coal at 5,000 kcal/kg with 84% efficiency (LHV) at rated output. Anthracite and lignite are accepted fuels, but consumption will differ and must be recalculated for their calorific values and characteristics.
The 84% figure is a rated-output value on an LHV basis. At reduced load, excess air and grate/draft settings change, and efficiency typically falls away from rating. The 20 t/h platform offers practical turndown for normal process swings, but sustained low-load operation is not its most efficient mode.
Feedwater and boiler water must be controlled to prevent scale, corrosion and carryover in the drum, threaded smoke tubes and steam circuit. This requires an appropriately sized external treatment train plus in-boiler chemical control, with limits set by the applicable water-quality standard for this pressure and the site's raw-water analysis.
| Model | DZL20-1.25-AII |
|---|---|
| Capacity | 20 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified in brief |
| Fuel | Bituminous coal, anthracite, lignite |
| Fuel consumption at rated output | 2857 kg/h (bituminous coal at 5,000 kcal/kg, 84% efficiency) |
| Efficiency | 84% (LHV basis) |
| Burner/control | Chain-grate firing; control package configured per project |
| Application | Continuous industrial process steam and district/campus steam networks |