CWDR Electric Hot Water Boiler, 0.35-2.8 MW
Horizontal electric hot water boiler, 0.35-2.8 MW at 85/60 °C, for district heating, hospitals and process hot water without a flu...
View detailsCarbon-fibre infrared hot air furnace, 0.35-2.8 MW, delivering clean hot air at 80-300 °C for drying, curing and coating lines.



An infrared hot air furnace is not a boiler and does not make steam. Carbon-fibre emitter tubes are mounted in a bank inside an insulated casing, a fan draws air across them, and the heated air leaves through a duct connection at 80 to 300 °C. The heat reaches the product by convection from the air, with a radiant component from the elements themselves where the duct is short and the line of sight is open.
This is the cleanest hot air available: no combustion products in the air stream, no moisture from a burner, no NOx, and no risk of a flame impinging on a coated web if the line stops. For coating, printing, food and pharmaceutical drying, that cleanliness is often worth more than the tariff difference against gas.
The emitter is a carbon-fibre filament sealed in a evacuated quartz tube. Carbon is close to a black body, so most of the input energy leaves as radiation in the medium-infrared band rather than as visible light — the conversion efficiency is above 95 per cent, and the tube runs cooler than a tungsten lamp of the same power. Compared with nickel-chrome elements, a carbon tube at the same wattage radiates at a higher surface temperature, which shortens the drying time for water-based coatings.
The tubes are arranged in frames on a 150 mm grid, so the radiant profile across the duct can be matched to the web width. Each frame is an independent heating zone with its own control, which lets the furnace deliver a narrow band of heat to one edge of a coating line without overheating the other.
The fan is sized for the design air volume at the system resistance, and the furnace casing is designed so that air passes the elements at a velocity high enough to carry heat away but low enough not to cool the tubes below their radiant temperature. An air-flow proving switch interlocks the elements: they cannot energise until the fan is running, and they trip within seconds if flow is lost. That single interlock prevents the most common failure mode of electric air heaters.
Temperature is controlled by thyristor or solid-state relay modulation rather than on/off contactors, so the outlet temperature holds within ±5 °C and the supply sees a smooth load instead of a series of steps. A thermocouple in the outlet duct and a second one on the element bank give the controller both the process variable and an over-temperature guard; the second sensor trips the elements if the fan degrades or a damper closes.
The furnace converts electricity to heat at 98 per cent, but the efficiency of the drying line is decided elsewhere. If the exhaust air leaves at 120 °C and the make-up air enters at 20 °C, most of the energy leaves with the exhaust. Recirculating 60 to 80 per cent of the exhaust back to the furnace inlet, with a proportional fresh-air damper for moisture control, is the single largest saving available and costs far less than additional heating capacity.
Where the process needs a solvent-laden exhaust, recirculation is limited by the lower explosive limit and the duct must be designed for the resulting concentration. In that case a secondary heat exchanger between exhaust and fresh air recovers part of the sensible heat without mixing the streams.
Typical duties are coil coating and curing, powder-coating ovens, textile stenters, paper and board drying, food dehydration, pharmaceutical tray drying, wood lacquer curing and plastic thermoforming. Outputs run from 0.35 MW to 2.8 MW, with air volumes from about 5500 to 44000 Nm³/h at a 180 K rise.
Selection needs four numbers: the mass flow of air, the inlet and outlet temperatures, the moisture or solvent load, and the allowable temperature uniformity across the duct. From those, the heat duty and the element bank follow. Units are built to order, typically delivered 25 to 45 days after drawing approval, with 5 to 10 days of site commissioning including loop tuning.
Yes, and it usually should. Recirculating 60-80 per cent of the exhaust back to the inlet cuts the heating load sharply. The limit is the moisture or solvent concentration in the return air, which must stay below the relevant safety threshold.
The air-flow switch drops the element supply within seconds and the over-temperature sensor on the element bank provides a second trip. The elements are designed to survive a brief loss of flow without damage.
The air stream contains no combustion products, so it is cleaner than any fuel-fired furnace. Final acceptance depends on the duct materials and filtration, which can be specified in stainless steel with HEPA filtration where required.
| Heat output | 350 kW | 700 kW | 1400 kW | 2100 kW | 2800 kW |
|---|---|---|---|---|---|
| Air volume (reference) | 5500 Nm³/h | 11000 Nm³/h | 22000 Nm³/h | 33000 Nm³/h | 44000 Nm³/h |
| Outlet air temperature | 80-300 °C | 80-300 °C | 80-300 °C | 80-300 °C | 80-300 °C |
| Temperature control | ±5 °C | ±5 °C | ±5 °C | ±5 °C | ±5 °C |
| Supply voltage | 380 V | 380 V | 380 V | 380 V | 380 V |
| Conversion efficiency | ≥98% | ≥98% | ≥98% | ≥98% | ≥98% |