0.5-10 t/h
Methanol and Multi-Fuel Fired Boiler, 0.5-10 t/h
Methanol, diesel and gas fired steam boiler, 0.5-10 t/h at 1.0-1.25 MPa, with a methanol-compatible fuel train, infrared flame sca...
View detailsThe WNS4-1.25-Q is a 4 t/h packaged steam boiler delivering 1.25 MPa at 194°C. It achieves 95% efficiency (LHV) with a low-NOx burner and suits process steam and heating loads.

The WNS4-1.25-Q is a three-pass wet-back fire-tube steam boiler with a rated capacity of 4 t/h. It produces saturated steam at 1.25 MPa and 194 °C. The packaged design includes a low-NOx burner and is configured for natural gas, LPG, light diesel, or heavy fuel oil. With a thermal efficiency of 95% (LHV basis), it is engineered for reliable, efficient steam generation in a compact footprint.
A 4 t/h boiler is well matched to medium-scale process steam and heating demands. Typical applications include:
This size bridges small packaged units and larger field-erected boilers, offering sufficient steam for multi-shift operations without excessive standby losses.
The rated fuel consumption is 297 Nm³/h when firing natural gas at 95% efficiency (LHV basis). This figure is derived from the heat input required to produce 4 t/h of steam at the stated pressure and temperature, divided by the boiler efficiency. The calculation assumes steady operation at the rated output and does not account for variations in fuel composition, ambient conditions, or part-load operation. For other fuels, consumption will differ based on calorific value and density; consult the burner data for LPG, light diesel, or heavy fuel oil.
At this capacity, the boiler exhibits stable part-load performance. The low-NOx burner is designed for modulating operation, typically with a turndown ratio of 3:1 or better, allowing efficient response to fluctuating steam demand. The three-pass wet-back design maintains good heat transfer at reduced loads, minimizing thermal stress. However, as with any fire-tube boiler, efficiency may decline slightly at very low loads due to increased relative heat losses. For optimal performance, size the boiler to operate between 50% and 100% of rated capacity for most of the operating time.
The WNS4-1.25-Q is a packaged boiler, factory-assembled and tested before shipment. It requires a level foundation, adequate ventilation, and clearance for maintenance access to the burner, controls, and inspection openings. The compact design reduces site work compared to field-erected boilers. No dimensions are provided here; refer to the general arrangement drawing for precise footprint and height. Installation must comply with local codes and regulations.
Proper water treatment is essential for reliable operation and longevity. The boiler requires softened feedwater with controlled alkalinity, dissolved oxygen, and suspended solids. A water treatment program should include:
Consult a water treatment specialist to design a program specific to your feedwater quality.
The boiler is equipped with a low-NOx burner and a control system that manages firing rate, flame supervision, and safety interlocks. The controls support modulating operation and can interface with building automation or plant control systems. Standard safety features include flame failure protection, high-pressure limit, and low-water cutoff. The burner is designed for quiet operation and low emissions, meeting applicable local emission standards.
The 4 t/h capacity is a versatile middle ground. Compared to a smaller 2–3 t/h unit, it offers greater steam output for growing processes without the higher capital cost and space requirements of a 6–8 t/h boiler. It provides a buffer for peak demands and future expansion while maintaining reasonable part-load efficiency. If your steam demand consistently exceeds 4 t/h, consider the next size up; if it is significantly lower, a smaller unit may reduce cycling losses. The WNS4-1.25-Q is optimized for plants with steady base loads and moderate fluctuations.
| Model | WNS4-1.25-Q |
|---|---|
| Capacity | 4 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 297 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Low-NOx burner, modulating controls |
| Application | Process steam, heating |
The WNS4-1.25-Q produces 4 tonnes of steam per hour at a pressure of 1.25 MPa and a temperature of 194 °C.
It can fire natural gas, LPG, light diesel, or heavy fuel oil. When operating on natural gas at rated output and 95% efficiency, fuel consumption is 297 Nm³/h.
The boiler requires softened feedwater with controlled alkalinity, dissolved oxygen, and suspended solids. A typical program includes softening, oxygen scavenging, pH control, and regular blowdown. Consult a water treatment specialist for site-specific advice.
| Model | WNS4-1.25-Q |
|---|---|
| Capacity | 4 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 297 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Low-NOx burner, modulating controls |
| Application | Process steam, heating |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.