20 t/h
20 t/h Gas/Oil Steam Boiler WNS20-1.25-Q
The WNS20-1.25-Q is a packaged three-pass wet-back fire-tube boiler delivering 20 t/h of steam at 1.25 MPa and 194 °C, firing natu...
View detailsThe SZS50-1.6-Q is a 50 t/h D-type double-drum water-tube boiler delivering 1.6 MPa steam at 204 °C. It achieves 95% efficiency (LHV) on natural gas, LPG, light diesel, or heavy fuel oil, with a rated fuel rate of 3715 Nm³/h.

The SZS50-1.6-Q is engineered for continuous industrial steam demand at 50 tonnes per hour. This size fits large process plants, district energy schemes, and central utility stations where a single boiler must carry a substantial base load without excessive footprint. Typical applications include chemical processing, food and beverage sterilization, pulp and paper drying, and textile finishing—operations that require steady 1.6 MPa steam at 204 °C and cannot tolerate frequent cycling.
The rated fuel consumption of 3715 Nm³/h is calculated from the boiler’s thermal output and the lower heating value (LHV) of natural gas at 95% efficiency. The steam output of 50 t/h at 1.6 MPa and 204 °C corresponds to a known enthalpy rise from feedwater to steam. Dividing the required heat input by the LHV of natural gas and the efficiency yields the stated figure. This value assumes continuous operation at rated capacity with natural gas; other fuels will have different volumetric or mass rates due to their respective heating values and densities.
At 50 t/h, the boiler’s large furnace and membrane-wall construction provide stable combustion and good turndown. The D-type double-drum arrangement allows effective circulation even at lower loads, and the burner modulation range supports efficient part-load operation. While efficiency will vary with load, the design minimizes losses at typical operating points between 60% and 100% of capacity. For loads below 50%, consult the factory for specific performance data.
The SZS50-1.6-Q is a shop-assembled D-type water-tube boiler with membrane walls, suitable for high-capacity service. It requires a dedicated boiler house with adequate headroom for drum removal and tube maintenance. Foundation loading and clearances for burner withdrawal, access doors, and flue gas ducting must be considered. The unit is not modular; site erection involves lifting the pre-assembled pressure parts onto the foundation. No specific dimensions or weights are provided here; refer to the general arrangement drawing for detailed space planning.
Proper water treatment is critical for this water-tube boiler to prevent scale, corrosion, and carryover. Feedwater should be demineralized or softened, with oxygen scavenging and pH control. Continuous blowdown and bottom blowdown are necessary to manage dissolved solids. The specific water quality limits depend on operating pressure and local conditions; adhere to the boiler manufacturer’s guidelines and relevant standards.
The SZS50-1.6-Q is supplied with a burner management system and combustion controls to maintain steam pressure and temperature. Typical controls include automatic modulation of fuel and air, flame monitoring, and safety interlocks. The control panel can interface with plant DCS for remote monitoring. For specific control specifications, consult the factory.
Choosing the 50 t/h model balances capacity and efficiency for plants with a base steam demand near this figure. A smaller unit would require multiple boilers or risk insufficient capacity during peak loads, while the next size up would add capital cost and footprint without matching the typical load profile. The SZS50-1.6-Q offers a sweet spot for high-capacity industrial users seeking reliability and operational economy.
| Model | SZS50-1.6-Q |
|---|---|
| Capacity | 50 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | Not specified |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 3715 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Not specified |
| Application | High-capacity industrial steam |
The SZS50-1.6-Q produces 50 tonnes of steam per hour at a pressure of 1.6 MPa and a temperature of 204 °C.
It can fire natural gas, LPG, light diesel, or heavy fuel oil. At rated output on natural gas, it consumes 3715 Nm³/h at 95% efficiency (LHV basis).
The boiler achieves 95% efficiency on a lower heating value (LHV) basis when operating at rated capacity with natural gas.
| Model | SZS50-1.6-Q |
|---|---|
| Capacity | 50 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | Not specified |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 3715 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Not specified |
| Application | High-capacity industrial steam |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.