
0.1-1 t/h
LSS Vertical Gas/Oil Steam Boiler, 0.1-1 t/h
Vertical three-pass packaged steam boiler for small loads, 0.1-1 t/h at 0.7-1.0 MPa, with a 1.3 m square footprint and fast cold s...
View detailsThe WNS1-1.25-Q is a 1 t/h packaged fire-tube steam boiler delivering 1.25 MPa at 194°C. It fires natural gas, LPG, light diesel or heavy fuel oil with a low-NOx burner and achieves 95% efficiency (LHV).

The WNS1-1.25-Q delivers 1 tonne of steam per hour at 1.25 MPa and 194°C. This size fits small-to-medium process loads: laundries, food processing, small chemical batches, greenhouses, and district heating substations. It is also common as a standby or backup unit in facilities with larger primary boilers, where a 1 t/h packaged boiler provides redundancy without excessive footprint.
The rated fuel consumption of 74 Nm³/h is for natural gas at rated output and 95% efficiency (LHV basis). It is calculated from the steam output and the fuel’s lower heating value, accounting for the boiler’s thermal efficiency. For other fuels in the allowed list—LPG, light diesel, heavy fuel oil—the volumetric or mass flow will differ because their heating values and densities differ. The 74 Nm³/h figure is a reference for natural gas only; actual consumption at part load will be proportionally lower.
At 1 t/h, the boiler’s three-pass wet-back fire-tube design and packaged low-NOx burner allow stable operation across a useful turndown range. The burner modulates to match steam demand, so fuel input reduces as load falls. Efficiency at part load remains high because the large water volume and wet-back reversing chamber promote good heat transfer and reduce cycling losses. However, very low loads may require occasional purge cycles to maintain stack temperature above dew point, especially with heavy fuel oil.
The WNS1-1.25-Q is a packaged unit: burner, controls, and safety devices are factory-mounted. Installation requires a level foundation, adequate ventilation, and clearance for burner maintenance and tube access. No dimensions are provided here; refer to the general arrangement drawing for exact footprint and clearances. The boiler is typically shipped assembled, reducing site work to connections for fuel, feedwater, steam, blowdown, and flue.
Proper water treatment is essential for fire-tube boilers. Feedwater should be softened to prevent scale, and chemical treatment should control corrosion and carryover. Blowdown—both bottom and surface—must be performed regularly to limit dissolved solids. The 1 t/h capacity means relatively small water inventory, so fluctuations in feedwater quality can affect steam purity; continuous monitoring is recommended.
The burner management system includes flame supervision, automatic ignition, and safety interlocks. Modulating controls maintain steam pressure by adjusting firing rate. A low-water cutoff, high-pressure limit, and safety valve are standard. The packaged design allows integration with plant SCADA or building management systems via optional interfaces.
Choosing 1 t/h rather than a smaller unit gives margin for peak demand and future expansion without frequent over-firing. Compared to the next size up (e.g., 1.5 or 2 t/h), the 1 t/h model has lower standby losses, quicker response to load changes, and a smaller footprint—advantages when steam demand is modest and intermittent. It avoids the cycling and efficiency penalties of an oversized boiler running at low load.
| Parameter | Value |
|---|---|
| Model | WNS1-1.25-Q |
| Capacity | 1 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified in brief |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 74 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Low-NOx burner, packaged controls |
| Application | Process steam, heating, standby |
The WNS1-1.25-Q produces 1 tonne of steam per hour at a working pressure of 1.25 MPa and a steam temperature of 194 °C.
Yes, the WNS1-1.25-Q is designed to fire natural gas, LPG, light diesel, or heavy fuel oil. The fuel consumption figure of 74 Nm³/h applies to natural gas at rated output and 95% efficiency; other fuels will have different flow rates.
Feedwater should be softened and chemically treated to prevent scale and corrosion. Regular blowdown is necessary to control dissolved solids. Given the 1 t/h capacity, consistent water quality is important to maintain steam purity and boiler life.
| Model | WNS1-1.25-Q |
|---|---|
| Capacity | 1 t/h |
| Pressure | 1.25 MPa |
| Steam temperature | 194 °C |
| Feedwater temperature | Not specified |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 74 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Low-NOx burner, packaged controls |
| Application | Process steam, heating, standby |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.