1-100 t/h
Low-NOx Condensing Gas Steam Boiler
Two-pass wet-back steam boiler with economiser and condensing tail, designed for 30 mg/Nm³ NOx and a stack temperature near 55 °C.
View detailsA packaged WNS gas steam boiler with clean steam generator, sized 1-10 t/h at 1.0-1.25 MPa, for fermentation, granulation, sterilization and HVAC humidification duties in pharmaceutical plants.

Pharmaceutical production draws steam at two distinct quality levels. Utility steam from the WNS gas boiler serves sterilization autoclaves, granulation and drying equipment, fermentation temperature control and HVAC humidification. Where steam contacts product, media or clean surfaces directly, a clean steam generator is added downstream of the boiler to produce clean steam from treated feedwater.
The package is specified at 1.0-1.25 MPa with a capacity range of 1-10 t/h. These parameters cover the typical spread of batch and continuous duties in a pharmaceutical plant, from small granulation suites to larger fermentation and sterilization blocks. Because the duties are batch-driven, the boiler must follow load changes without pressure collapse at the point of use.
Sizing starts from the connected load, not from a single peak figure. Sterilizers and granulation equipment draw steam in discrete batches, while HVAC humidification and fermentation control add a more continuous base. The recommended capacity is set so that the largest single batch draw plus the continuous base stays within the boiler’s rated output at 1.0-1.25 MPa.
Clean steam generation adds a further demand on the utility side, since the generator consumes boiler steam to produce clean steam. This load should be counted in the sizing calculation. Where several batch duties can coincide, the sizing basis should state the assumed simultaneity, so the selected 1-10 t/h unit matches the real operating pattern rather than the arithmetic sum of nameplates.
The WNS boiler is gas-fired, with fuel options covering natural gas and other gaseous fuels available at site. The three-pass wet-back WNS configuration is the basis of the package. Efficiency depends on the final configuration, including whether heat recovery from flue gas is included; the exact efficiency figure is fixed at the proposal stage against the selected fuel and stack conditions.
Fuel selection should reflect site supply and the plant’s steam demand profile. For plants with a strong continuous base load, a single WNS unit sized to that base with batch peaks covered by the same unit is a common arrangement. The boiler package is supplied as a packaged unit to reduce site erection work.
Documented water quality is a core requirement for this application. The package includes water treatment as part of the scope, and the treatment train is selected to meet the feedwater and boiler water limits required by the boiler and by the clean steam generator. Records of water quality parameters form part of the operating documentation.
Clean steam for direct contact is produced in a separate clean steam generator, fed with treated water and heated by utility steam. This separation keeps the clean steam circuit distinct from the boiler circuit. Steam quality for the clean steam supply is defined by the generator specification and the feedwater quality; both are fixed during engineering and documented for validation support.
The boiler package includes a burner management and boiler control system covering firing rate control, pressure control, flame monitoring and interlock functions. Controls are configured to hold steam pressure within the operating band at 1.0-1.25 MPa under the batch load pattern described above. Safety functions include low-water protection, overpressure protection and flame failure shutdown, integrated with the burner management system.
Validation support is part of the package scope. This covers the documentation needed by the plant’s qualification process, including water quality records and control system documentation. The specific validation documents required should be listed in the enquiry so they can be included in the proposal.
To prepare a proposal, send the required steam capacity in t/h and the operating pressure within the 1.0-1.25 MPa range. State the duties to be served and, where known, the batch pattern and simultaneity assumptions. Provide the fuel available at site and its supply conditions. Describe the water source and any existing water treatment. List the clean steam demand and the points of direct contact. Finally, list the validation documents required, so the documentation scope can be confirmed in the proposal.
Utility steam from the WNS boiler serves sterilization, granulation, fermentation control and HVAC humidification. Where steam contacts product or clean surfaces directly, a clean steam generator produces clean steam from treated feedwater, keeping the clean steam circuit separate from the boiler circuit.
Size from the connected load: the largest single batch draw plus the continuous base load should stay within the rated output at 1.0-1.25 MPa. The clean steam generator's utility steam demand must be counted, and the assumed simultaneity of batch duties should be stated.
Validation support is part of the package scope, covering documented water quality records and control system documentation. The specific validation documents required should be listed in the enquiry so they can be confirmed in the proposal.
| Typical capacity | 1-10 t/h |
|---|---|
| Pressure | 1.0-1.25 MPa |
| Fuel options | Natural gas and other gaseous fuels available at site |
| Boiler type | WNS packaged gas steam boiler, three-pass wet-back |
| Efficiency | Fixed at proposal stage against selected fuel and stack conditions |
| Steam quality | Clean steam from dedicated clean steam generator for direct contact |
| Controls | Burner management and boiler control with pressure control, flame monitoring and interlocks |
| Water treatment | Included in scope; documented water quality records |
| Scope of supply | WNS boiler, burner, controls, water treatment, clean steam generator, validation support documentation |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.