1.5 t/h at 0.8 MPa is the working point for a tea processing plant in Sylhet, Bangladesh, where tea waste and branch wood are available on the estate but only in the pruning season. The unit was selected on that operating pattern rather than on a catalogue rating, and the difference shows in how it holds pressure on the worst shift of the week.

Two boilers with the same efficiency can have very different steam costs, because the delivered fuel price, moisture and ash decide more than two points of combustion efficiency. A biomass plant that trucks fuel 300 km is buying diesel with extra steps; a plant next to a rice mill or a sawmill has a structural advantage that no burner tuning can match.

Numbers that decide the design

At 1.5 t/h and 0.8 MPa the unit absorbs about 1.1 MW. On wood chips at roughly 79% efficiency, full-load demand is about 0 kg/h. The figures are stated at the site’s conditions, because ambient temperature, altitude and fuel analysis all move them.

Design point
Item Value
Rated output 1.5 t/h
Pressure / temperature 0.8 MPa
Fuel wood chips
Full-load fuel demand 0 kg/h
Thermal efficiency about 79%

What to watch on site

The ten-year view includes fuel, maintenance, operators, water treatment and downtime. A cheaper boiler with a difficult grate can consume the difference in spare parts and lost production. For export sites, the spare-parts lead time belongs in the same calculation, because a two-week wait for a $200 part can stop a plant that earns $20,000 a day.

Site note: tea waste and branch wood are available on the estate but only in the pruning season. The operators log header pressure and stack temperature every two hours, which is enough to see fouling and load drift before either becomes a shutdown.

Why it matters

Fuel logistics beats boiler efficiency is not a detail to settle after the order. It decides the shell size, the burner, the feedwater train and the maintenance calendar, and it is cheaper to get right in the specification than in the boiler house.

Equipment used in this kind of plant: dzl chain grate biomass boiler and water treatment system. The industry side is covered in this solution page, and project cases show comparable installations.

Background reading: external reference on steam and process heat.

Questions plant engineers ask

How should fuel be compared?

On delivered cost per tonne of steam, not per tonne or per MJ. Moisture, ash and boiler efficiency all change the number.

What is the biggest hidden cost in a boiler project?

Fuel logistics and downtime. Both are usually larger than the difference between two equipment quotations.

Related note: 4 t/h Biomass steam boiler in Indonesia: Fuel preparation decides the boiler’s output