0.1-1 t/h from 50, 60, 80 or 100 kW modules
Modular Electric Steam Generator, 0.1-1 t/h
Parallel 50-100 kW electric steam modules, 0.1-1 t/h at 0.4-0.7 MPa, staged by PLC so part-load efficiency holds and one module is...
View detailsThe WDR1-0.7 is a 1 t/h electric steam boiler producing 0.7 MPa steam at 170 °C. Heating elements sit in a horizontal shell with no flue or fuel storage, drawing 70 kW at rated output at 98% efficiency.

The WDR1-0.7 is the 1 t/h model in the WDR Electric Steam Boiler series. It delivers steam at 0.7 MPa and 170 °C using electric heating elements mounted in a horizontal shell. There is no flue and no fuel storage, so the unit has no combustion air path, no stack and no on-site fuel inventory to manage.
At 1 t/h, the WDR1-0.7 fits process loads that need a steady, moderate steam supply rather than large plant-wide demand. Typical matches include:
The 0.7 MPa / 170 °C combination suits equipment rated for this pressure class; confirm each consumer’s rating before connection.
The brief gives 70 kW at rated output as electric power at 98% efficiency (LHV basis). The figure is the electrical input needed to raise steam at the rated 1 t/h output, stated at the rated efficiency. Because the boiler is electric, the fuel rate is expressed as electrical power rather than a volume or mass of combustible fuel. At part load, input power falls with steam demand; the 70 kW value applies at rated output only.
Electric element heating can be staged, so at 1 t/h the boiler can follow demand below rated output by energising fewer elements rather than cycling a single large heat source. This gives relatively smooth modulation across the useful range. Efficiency at part load depends on element staging and shell losses; the 98% figure is the rated-point value on an LHV basis. Operators should expect standby losses to matter more at low output, so matching the unit to average rather than peak demand supports efficient running.
The horizontal shell and absence of a flue simplify siting: no stack, no combustion air ducting and no fuel storage area are required. The unit still needs electrical supply capacity for the 70 kW input, a feedwater connection, steam outlet, blowdown and drainage, and access for element service. Clearances for maintenance and electrical safety should be planned with the installing engineer. No dimensions or weights are stated here; refer to the model drawing for those.
As with any steam boiler, feedwater quality governs shell and element life. Scale on heating elements reduces heat transfer and can shorten element life, so feedwater conditioning and blowdown practice should follow the water-treatment programme for the site. The brief does not specify feedwater temperature; the spec table lists it as not stated in the brief, and it should be confirmed for the installation.
The WDR1-0.7 is supplied with burner/control arrangement as listed in the specifications. Electric units use element staging and pressure-based control to hold steam pressure at the 0.7 MPa setpoint. Control detail beyond the brief is not stated here; confirm the control package with the supplier.
Choose the 1 t/h WDR1-0.7 when demand sits near this output and 0.7 MPa steam is sufficient. The next size up would add capacity that may run lightly loaded, raising relative standby losses; the next size down would leave little margin for peaks. The 1 t/h unit balances margin and part-load economy for loads in this band.
| Parameter | Value |
|---|---|
| Model | WDR1-0.7 |
| Capacity | 1 t/h |
| Pressure | 0.7 MPa |
| Steam temperature | 170 °C |
| Feedwater temperature | Not stated in brief |
| Fuel | Electricity |
| Fuel consumption at rated output | 70 kW (electric power, 98% efficiency) |
| Efficiency | 98% (LHV basis) |
| Burner/control | Electric heating elements in horizontal shell; no flue, no fuel storage |
| Application | Process steam at 0.7 MPa for modest continuous loads |
It produces 1 t/h of steam at 0.7 MPa and 170 °C, using electric heating elements in a horizontal shell.
70 kW at rated output, stated as electric power at 98% efficiency on an LHV basis. Input falls as steam demand drops below rated output.
No. The unit is electric, with heating elements in a horizontal shell, so there is no flue and no fuel storage. It does require electrical supply capacity for the 70 kW input and normal feedwater, steam and blowdown connections.
| Model | WDR1-0.7 |
|---|---|
| Capacity | 1 t/h |
| Pressure | 0.7 MPa |
| Steam temperature | 170 °C |
| Feedwater temperature | 20 °C (105 °C with deaerator) |
| Fuel | Electricity |
| Fuel consumption at rated output | 70 kW (electric power, 98% efficiency) |
| Efficiency | 98% (LHV basis) |
| Burner/control | Electric heating elements in horizontal shell; no flue, no fuel storage |
| Application | Process steam at 0.7 MPa for modest continuous loads |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.