Steam and Thermal Oil Systems for Textile Dyeing and Finishing

Batch dyeing steam, stenter heat and cylinder drying in one plant: coincidence factors, a 3.4 MW peak calculation and thermal oil design limits.

8 t/h Gas Steam Boiler for a Textile Plant in Bucaramanga, Colombia – Yuanda Boiler

Process heat demand: batch steam and continuous hot air

A dyehouse buys heat in two different forms, and they rarely come from the same unit. Jet and package dyeing machines consume steam in batches: a machine fills, heats a liquor volume to 130 °C, holds, cools and drains, then repeats. Stenters and curing ovens consume heat continuously at 180-220 °C, which saturated steam cannot reach at any sensible pressure. Between them sit the cylinder dryers, running at a steady 0.4-0.6 MPa, and the printing steamer at 0.2 MPa.

The batch load sets the boiler size and is deceptive. Ten dyeing machines rarely heat up together, but six do when a shift starts and the plan pushes one shade family through in parallel. A boiler sized on the sum of all ten is oversized by 60%; one sized on the daily average collapses at the first colour change.

The stenter load is easier to calculate because it is continuous, and it is the load most often left out of the enquiry. Where a mill has no gas grid, or the stenter exhaust is used for heat recovery, a thermal oil heater is the practical answer and belongs in the same plant room.

Equipment train: two circuits, one plant room

The steam side is a packaged fire-tube boiler from 4 to 20 t/h at 1.0 MPa, with a matched low-NOx burner, softener and, above 4 t/h, a deaerator. Jet dyeing machines are the most sensitive users: they need 0.4-0.6 MPa at the machine inlet and a stable pressure during the heat-up ramp, because a falling header pressure lengthens the cycle and causes shade variation between batches.

The thermal oil side is a horizontal coil heater of 350-5,800 kW, with a circulating pump set, an expansion tank and a nitrogen blanket on the tank if the oil is expected to last. Thermal oil is chosen for stenters because it delivers 280-300 °C at atmospheric pressure, so the plant avoids a high-pressure steam system for one or two users.

Water treatment matters here: textile water is often hard and high in chloride, and dyehouse condensate carries dye, salt and caustic. Only dryer and heat exchanger condensate returns to the hotwell.

Parameter Value Note
Steam capacity 8 t/h at 1.0 MPa 179.9 °C saturated
Peak steam demand 7.5 t/h six machines in heat-up
Thermal oil capacity 2,000 kW two stenters
Oil supply / return 280 / 260 °C film temperature below 320 °C
Oil working pressure 0.6 MPa pump head only
Condensate return 35% at 85 °C dryer section only
Fuel Natural gas, 35.6 MJ/Nm³ LHV basis

Worked example: a dyehouse with ten jets and two stenters

Each jet machine holds 3,000 litres of liquor. Heating from 30 °C to 130 °C takes 3,000 kg × 4.19 kJ/kgK × 100 K = 1.257 GJ. Add 8% for vessel mass and standing losses, and the batch needs 1.36 GJ. Spread over a 40-minute heat-up (2,400 s), that is 566 kW per machine. Six machines ramping together give 3.4 MW.

The rest of the steam load is continuous: cylinder dryers 1.1 MW, hot water for washing 0.35 MW. Total 4.85 MW, which at 2,338 kJ per kilogramme of steam (1.0 MPa, 105 °C feed) is 7,466 kg/h — 7.5 t/h, so an 8 t/h boiler with 7% margin.

On the oil side, a five-chamber stenter evaporating 1,100 kg of water per hour needs 1,100 × 2,257 kJ/kg = 2.48 GJ/h, or 690 kW of latent heat. Fabric heating, fresh-air make-up and casing losses add about 35%, so each stenter draws roughly 930 kW and the pair draws 1.9 MW. A 2,000 kW heater covers both with 5% spare.

Check the oil flow: at 2,000 kW, a 20 K drop and a specific heat of 2.2 kJ/kgK, the circulation is 2,000 / (2.2 × 20) = 45 kg/s, about 190 m³/h at 850 kg/m³. That flow must be available before the burner fires and must be proven by a flow switch, not by pump status.

Efficiency, operating cost and compliance

What moves the fuel bill

On the steam side the levers are familiar: an economiser worth 3-4 points, 3% O2 instead of 6%, and blowdown kept near 3% by good softener control. Each point is worth about 21,000 Nm³ a year at 4,500 hours, so the economiser pays back quickly.

On the oil side the largest loss is usually not the heater but the distribution. Uninsulated oil lines, a leaking flange and an over-temperature bypass all raise return temperature and force the burner to make up heat that was already paid for. The second largest is film temperature: running the heater at low flow to hold a high supply temperature cokes the oil on the coil wall, and the coke layer costs efficiency permanently. Minimum flow protection and a 20-30 K design drop are the defence.

Emissions and compliance

Both circuits normally fall under one site permit. NOx at 30 mg/Nm³ is achievable on gas with flue-gas recirculation; 60-80 mg/Nm³ is typical without it. Stenter exhaust is separate: it carries oil mist and condensed volatiles, and many districts require treatment regardless of what the boiler emits.

Thermal oil systems add a compliance point of their own. The oil is a hazardous material when hot, the expansion tank must be vented safely, and the heater needs a high-temperature cut-out independent of the control loop. A leak into a stenter duct is a fire risk, so the coil and its flanges should be inside a bunded area with detection.

Where specifications go wrong, and what we need to quote

Common errors

  • Adding up all dyeing machines instead of applying a coincidence factor of 0.5-0.6.
  • Forgetting that a 130 °C jet machine needs 0.4-0.6 MPa at the inlet after the control valve, not at the boiler.
  • Running one oil temperature for all users, which forces the coldest user to throttle and the hottest to run the heater flat out.

Information we need

  • Number and volume of dyeing machines, heat-up time and maximum temperature.
  • Stenter chambers, web width, line speed and evaporation rate in kg/h.
  • Steam pressure required at each machine inlet, not only at the boiler.
  • Fuel available, and whether a gas grid connection exists at the site.
  • Water hardness and chloride level, and the permitted effluent route for dyehouse condensate.
  • Space for two plant rooms or one, and the noise limit at the boundary.

With those figures we can size both circuits and check the coincidence assumption against your shift pattern.

Frequently asked questions

Why do stenters need thermal oil rather than steam?

Stenters dry at 180-220 °C air temperature. Saturated steam at a workable pressure cannot reach that, and high-pressure superheated steam would need a pressure system far beyond what one user justifies. Thermal oil delivers 280-300 °C at close to atmospheric pressure, so the heater stays simple.

How many dyeing machines should be counted as simultaneous?

Between half and two thirds of the installed machines, depending on how the dye plan is batched. Six out of ten is a common design figure. Ask the dyehouse manager how many machines can be in heat-up at the same time at shift start; that number, not the installed count, sizes the boiler.

What steam pressure does a 130 °C jet dyeing machine need?

The liquor runs at 130 °C under its own pump pressure, and the heat exchanger needs a useful approach temperature, so 0.4-0.6 MPa at the machine inlet is usual. Allow for the control valve drop and the main loss when setting the boiler pressure.

Can dyehouse condensate be returned to the boiler?

Only from the clean users: cylinder dryers, heat exchangers and hot water sets. Condensate from dyeing and washing carries dye, salt and caustic and belongs in effluent treatment. Returning contaminated condensate raises blowdown and can foam the boiler.