Two methods, two different questions
The direct method divides useful heat output by fuel energy input. It is simple, needs only a steam meter, a feedwater temperature and a gas meter, and it answers the question the accounts department asks: how much did I pay for the steam I got? Its weakness is that it says nothing about where the rest went, and a 2% error in the steam meter becomes a 2% error in the answer.
The indirect method adds up the losses and subtracts them from 100. It needs more measurements but each one points at a specific cause: flue gas temperature, oxygen, unburnt carbon, radiation. For anyone trying to improve a boiler rather than just report on it, the indirect method is the useful one, and the two methods should agree within about one percentage point when both are done properly.
The loss stack
Five losses account for almost everything. Dry flue gas loss is the largest: the mass of nitrogen, carbon dioxide and excess oxygen leaving the stack above ambient temperature. Moisture loss is the heat that superheats the water vapour from combustion and from the fuel. Unburnt loss is carbon in the ash or CO in the gas. Radiation and convection loss is heat leaving the casing. Blowdown loss applies to steam boilers only.
On a gas-fired boiler, dry flue gas loss typically runs 4-6% with a 150 °C stack, moisture 1-2%, radiation 0.5-1.5%, unburnt 0.1-0.5% and blowdown 1-2%. On a biomass grate boiler, dry flue gas loss is higher because the flue volume is larger and the stack is hotter, and unburnt carbon can reach 8-12%, which is why biomass efficiency sits at 80-84% rather than 92-95%.
A worked calculation for a 10 t/h gas boiler
The boiler raises 10 t/h of saturated steam at 1.25 MPa with feedwater at 60 °C, burning 780 Nm³/h of natural gas with a lower heating value of 35.59 MJ/Nm³. Stack temperature is 150 °C, ambient is 25 °C, and the flue gas oxygen is 3.6% dry.
Useful heat is 10,000 kg times (2,785 – 251) kJ/kg, or 25.34 GJ/h. Fuel input is 780 times 0.03559, or 27.76 GJ/h. Direct efficiency is 25.34 divided by 27.76, or 91.3%.
For the indirect method, first find excess air. At 3.6% O2, excess air is 21/(21-3.6), or 1.21. Stoichiometric combustion of methane needs 9.52 Nm³ of air per Nm³ of gas, so the dry flue gas is 1.0 Nm³ of CO2, 9.08 Nm³ of nitrogen and 0.41 Nm³ of excess oxygen, a total of 10.49 Nm³ per Nm³ of gas.
With a mean specific heat of 1.34 kJ/Nm³·K over the 125 K range, dry flue gas loss is 10.49 times 1.34 times 125, or 1,757 kJ per Nm³ of gas. Divided by 35,590 kJ, that is 4.94%.
Moisture loss is the superheat in 2 Nm³ of water vapour per Nm³ of gas, about 1.1% on a lower heating value basis. Radiation from the casing, measured by surface temperature survey, is 1.3%. Unburnt loss, from CO at 25 ppm, is 0.2%. Blowdown at 4% costs 1.0%. The total is 8.54%, so indirect efficiency is 91.46%, within 0.2 of a point of the direct figure.
| Loss | Basis | This boiler | Typical range, gas |
|---|---|---|---|
| Dry flue gas | Mass flow, cp, stack minus ambient | 4.94% | 4.0-6.5% |
| Moisture | Superheat of combustion water vapour | 1.10% | 0.9-1.5% |
| Radiation and convection | Casing surface survey | 1.30% | 0.5-1.5% |
| Unburnt gas and carbon | CO and ash carbon | 0.20% | 0.1-0.5% |
| Blowdown | Rate times saturation enthalpy | 1.00% | 1.0-2.5% |
| Total loss | Sum | 8.54% | 7-12% |
What the numbers say to change
The dry flue gas loss dominates, and it has two levers: stack temperature and excess air. Cutting excess air from 3.6% O2 to 3.0% reduces the flue volume by about 3% and the loss by 0.15 points, which is small but free. Fitting an economiser to take the stack from 150 °C to 95 °C cuts the dry gas loss to 2.77%, a gain of 2.2 points, and saves about 18 Nm³/h of gas at this load.
Radiation loss is worth a walk round the casing with a thermal camera. A casing at 60 °C instead of 35 °C on a 10 t/h boiler is roughly 0.8 points of efficiency, and it usually means failed insulation or a leaking gasket at a manway, both cheap to fix.
Measurement errors that make audits disagree
The first is the oxygen reference. A NOx or O2 reading at the stack is wet or dry depending on the analyser, and the loss calculation must use dry gas. A wet reading of 4% O2 is about 4.5% dry, which changes excess air by 5% and the flue loss by 0.2 points.
The second is the fuel analysis. Using a default 35.59 MJ/Nm³ when the local gas is 34.5 shifts the answer by 3%, which is larger than most of the improvements being measured. Take a gas sample or use the supplier’s monthly certificate.
The third is the boundary. Blowdown, deaeration steam and boiler-house radiation belong to the boiler; condensate return temperature belongs to the system. An efficiency figure without a stated boundary is not comparable with any other figure.
Finally, steady state. A boiler tested 10 minutes after a load change is still warming its refractory and its water, and the result will be low by 1-2 points. Run at each load for 30 minutes before logging, and take three sets of readings.
Using the result
Report efficiency at three loads with the boundary, the fuel analysis and the reference conditions attached. Compare the result with the guarantee and with the previous year’s test on the same basis. Then use the loss stack to decide what to fix: stack temperature points to the economiser, oxygen points to the burner and the air dampers, casing temperature points to insulation, and unburnt carbon points to the grate or the fuel.
A boiler that tests at 91% is not necessarily a bad boiler. It may be a boiler with no economiser and a 150 °C stack, which is exactly what the loss stack says, and the fix is known, priced and measurable. That is the value of the indirect method: it converts a single disappointing number into four specific jobs.