20 t/h
20 t/h Water-Tube Gas/Oil Steam Boiler SZS20-1.6-Q
The SZS20-1.6-Q is a 20 t/h D-type double-drum water-tube boiler producing steam at 1.6 MPa and 204 °C. It achieves 95% efficiency...
View detailsThe SZS10-1.6-Q is a 10 t/h D-type double-drum water-tube steam boiler rated at 1.6 MPa and 204 °C, firing natural gas, LPG, light diesel or heavy fuel oil at 95% efficiency (LHV basis).

The SZS10-1.6-Q is a member of the SZS water-tube gas/oil steam boiler series. It is a D-type double-drum unit with membrane walls, rated at 10 t/h capacity, 1.6 MPa design pressure and 204 °C steam temperature. The series is built for high-capacity duty, and this model sits at the 10 t/h point of that range.
Fuel flexibility covers natural gas, LPG, light diesel and heavy fuel oil. Rated efficiency is 95% on an LHV basis.
At 10 t/h, this unit suits plants whose steam demand is steady and substantial: process heating across multiple users, continuous duty in food, chemical, textile or paper operations, and district or campus steam headers where a single boiler carries the base load. It is also a common choice where two units are installed so that one can be held in reserve or run in parallel during peaks.
Below this size, a 6 or 8 t/h unit leaves little margin for a single large consumer or for growth. Above it, the next step up commits more floor area, more auxiliary capacity and a larger water-treatment duty before the load is actually there. The 10 t/h point is often the practical balance between having reserve capacity and not carrying unused capital.
The published fuel rate is 743 Nm³/h at rated output, stated for natural gas at 95% efficiency. It follows from the rated steam output and the fuel’s lower heating value: the heat required to raise 10 t/h of steam to the stated conditions is divided by the LHV of the gas and by the 95% efficiency figure. Because the number is tied to LHV and to natural gas, it should be read as the rated-output reference point. LPG, light diesel and heavy fuel oil have different heating values and densities, so their consumption figures differ and are calculated on the same basis.
Water-tube construction with membrane walls gives this capacity a responsive furnace. At part load the unit modulates rather than cycling on and off, which matters at 10 t/h because the turndown range covers a useful band of the plant’s demand without frequent starts. Efficiency at part load is lower than the 95% rated figure, as with any boiler, and the fall-off depends on how far the load drops and on the excess air maintained by the burner. Sizing the burner and control package to the actual load profile, rather than to the nameplate alone, is what preserves part-load performance.
The D-type layout places the drums and tube banks in a compact arrangement, with the burner at the front and the convection section behind. In general terms, the installation needs a defined boiler house footprint with access for the burner, the stack connection, feedwater and steam piping, and room for maintenance on the drum and tube access points. Foundations must carry the operating weight of a water-filled unit. Site-specific dimensions, weights and clearances are confirmed at the engineering stage against the project layout.
Water-tube boilers at this pressure require disciplined feedwater and boiler water chemistry. Scale and carryover affect tube life and steam quality more directly than in a small fire-tube unit. A treatment programme matched to the site’s raw water, with continuous blowdown and monitoring of the parameters appropriate to 1.6 MPa operation, is part of the installation, not an optional extra.
The burner and control package handles modulation, flame supervision and the safety interlocks required for unattended or supervised operation. Control scope is agreed per project; the boiler is supplied to integrate with the plant’s steam demand signal and with the feedwater and blowdown systems.
| Parameter | Value |
|---|---|
| Model | SZS10-1.6-Q |
| Capacity | 10 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | To be confirmed per project |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 743 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with flame supervision and safety interlocks; scope per project |
| Application | Continuous process steam, multi-user plant headers, base-load duty |
It suits plants with a steady, substantial demand — multi-user process headers, continuous duty in food, chemical, textile or paper operations, or base-load service where a second unit covers peaks and reserve. It is a common size where a single large consumer or moderate growth must be covered without stepping up to a larger frame.
It is the rated-output consumption for natural gas at 95% efficiency on an LHV basis: the heat needed to produce 10 t/h of steam at 1.6 MPa and 204 °C is divided by the gas LHV and by the efficiency. Other fuels have different heating values, so their consumption is calculated on the same basis rather than taken from this figure.
Yes. The model is specified for natural gas, LPG, light diesel and heavy fuel oil. The fuel rate quoted applies to natural gas; consumption for the liquid fuels differs and is calculated from their heating values. Fuel-specific arrangements are agreed at the engineering stage.
| Model | SZS10-1.6-Q |
|---|---|
| Capacity | 10 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | To be confirmed per project |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 743 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with flame supervision and safety interlocks; scope per project |
| Application | Continuous process steam, multi-user plant headers, base-load duty |