NOx limits for industrial boilers are only meaningful when they are written with a reference oxygen level, a load point, a fuel specification and a test method. A bare figure such as “<30 mg/Nm³ NOx” can mean very different things at 3% O₂ dry versus 5% O₂ dry, at 100% load versus 50% load, and with or without flue gas recirculation (FGR) in service. This article explains the parameters to fix in a specification so that burner suppliers, boiler suppliers and test houses are all measuring the same thing.

1. Always state the reference oxygen

Measured NOx concentration depends strongly on the excess air at the measurement plane. To compare values, emissions are normalised to a dry flue gas with a defined O₂ content. Common conventions:

  • 3% O₂ dry — typical for natural gas firing in many European and Asian permit regimes.
  • 5% O₂ dry — used in some jurisdictions and for certain liquid fuels.
  • 6% O₂ dry — often applied to solid fuels or specific local rules.

Converting between references is not a simple ratio; use the standard correction formula based on the measured and reference O₂. As a rule of thumb, a reading at 5% O₂ is roughly 10–15% lower than the same physical emission expressed at 3% O₂, but always calculate rather than estimate. Specify the reference O₂, the dry/wet basis, and whether NOx is expressed as NO₂ equivalent (NOx as NO₂ is the usual convention).

2. Burner class: what the numbers typically mean

Burner classifications are not standardised worldwide, but the following bands are widely used for gas-fired packaged boilers. Values are indicative and must be confirmed by the burner supplier for the specific firing rate, furnace geometry and fuel.

Class (typical label) NOx range, mg/Nm³ @ 3% O₂ dry NOx range, ppm @ 3% O₂ dry (approx.) Typical measures
Standard 150–250 ~75–125 Staged air, conventional flame
Low-NOx 80–150 ~40–75 Air staging, flue gas recirculation (FGR), lean premix
Ultra-low-NOx 30–80 ~15–40 Heavy FGR (10–25% of flue gas), premix surface or radiant burners, tight O₂ control
Very low (special designs) <30 <15 Full premix, high FGR, possible SCR for stringent cases

Assumptions: natural gas (H-gas, ~35.9 MJ/Nm³ LHV), ambient combustion air at 20 °C, steady-state operation at 80–100% load, dry basis. ppm values assume a molecular weight conversion of approximately 2.05 mg/Nm³ per ppm for NO₂ at standard conditions; use the exact conversion for your contract.

3. Flue gas recirculation (FGR): specify the rate and the penalty

FGR lowers flame temperature and therefore thermal NOx. Typical FGR rates are 5–10% for low-NOx and 10–25% for ultra-low-NOx burners, expressed as a percentage of flue gas volume relative to combustion air or total flue gas — state which basis you use. FGR affects:

  • Fan power: additional recirculation fan or higher forced-draft pressure, typically adding 1–5% to auxiliary power.
  • Turndown: FGR often limits stable turndown; specify the minimum load at which the NOx guarantee applies.
  • Condensation risk: recirculated flue gas below the acid dew point can cause corrosion in ductwork; specify materials and insulation.
  • Stability: high FGR can cause flame instability or CO rise; require the supplier to state CO and O₂ at the guaranteed NOx point.

If your site has limited space or stack height, discuss the layout early — see our product range for boiler and burner configurations.

4. Low-NOx versus ultra-low-NOx: what changes in the boiler

Moving from low-NOx to ultra-low-NOx is not only a burner swap. It usually requires a larger furnace volume (lower heat release per unit volume), a different furnace shape to accommodate a longer flame, tighter air/fuel ratio control (O₂ trim with fast actuators), and often a larger stack or ID fan to handle FGR. Specify:

  • Furnace heat release rate (kW/m³) and its basis.
  • Required turndown with NOx compliance at each load point (e.g. 100%, 75%, 50%).
  • Allowable CO and O₂ at the guaranteed NOx point.
  • Whether the guarantee applies with or without economiser, air preheater or FGR in service.

Cost is driven by furnace size, burner complexity, FGR fan and ducting, control instrumentation, and the testing scope — not by a single NOx number. For sizing context, see the capacity and cost guide.

5. Testing: how the limit is verified

Specify the test method, the measurement plane, the load points and the averaging period. A typical acceptance test uses a calibrated portable flue gas analyser (chemiluminescence or electrochemical/NDIR as agreed) at a straight duct section with at least 3 diameters upstream and 1–2 downstream of disturbances. Require:

  • Three runs per load point, each of at least 20–30 minutes after steady state.
  • Simultaneous O₂, CO, NOx and flue gas temperature records.
  • Fuel composition and flow measurement (or heat input calculation) during the test.
  • Correction to the agreed reference O₂ and dry basis.
  • Ambient conditions (temperature, humidity, barometric pressure).

If the guarantee is stated at 3% O₂ but the boiler runs at 5% O₂ in normal operation, the measured value will differ; agree in advance whether the guarantee is at a fixed O₂ or at a fixed load with actual O₂.

Checklist for your NOx specification

  • ☐ NOx limit with units (mg/Nm³ or ppm), reference O₂, dry basis, NOx as NO₂.
  • ☐ Fuel specification (type, LHV, composition, sulphur).
  • ☐ Load points for the guarantee (100%, 75%, 50%, minimum load).
  • ☐ FGR rate and basis, if FGR is required.
  • ☐ Allowable CO and O₂ at the guaranteed NOx point.
  • ☐ Test method, measurement plane, averaging period and instrument class.
  • ☐ Whether economiser, air preheater or FGR must be in service during the test.
  • ☐ Turndown requirement with NOx compliance.

What to send us for a proposal

To prepare a technical proposal, send: required steam or hot water output (kg/h or kW), design pressure and temperature, fuel type and supply conditions, the NOx limit with reference O₂ and load points, available space and stack height, FGR constraints, electrical supply and control requirements, and any local permitting basis. We will respond with a burner and boiler configuration, the expected NOx range at your load points, and the testing scope — without quoting prices until the scope is fixed.