1-100 t/h (0.7-70 MW)
WNS Gas/Oil Steam Boiler, 1-100 t/h
Packaged three-pass wet-back fire-tube steam boiler for gas and oil, 1-100 t/h at 1.25 MPa, with matched modulating burner and ful...
View detailsA 4 t/h gas steam boiler supplies baking, cooking and CIP steam at a confectionery plant in Tashkent, with a stainless feedwater system and low-NOx burner.

The confectionery plant in Tashkent makes biscuits, wafers and boiled sweets. Steam goes to baking ovens, jacketed cooking pans, the CIP set and a small pasteuriser. Because some steam is used in direct contact and in cleaning, the plant wanted clean steam quality: no carry-over, no treatment chemicals in the steam, and a feedwater system that could be sanitised.
The boiler is a 4 t/h WNS fire-tube unit at 1.0 MPa. The load is 2.5-3 t/h for most of the day, peaking at 3.8 t/h when the ovens and the cooking pans run together.
At 1.0 MPa, saturated steam is 184 °C. The boiler has a 0.3 m steam space and a baffle type separator, and the plant runs at 2,500 ppm dissolved solids with automatic conductivity blowdown. That combination keeps carry-over below 0.5% and avoids the waxy deposits that used to appear on the cooking pan jackets.
All wetted feedwater piping is stainless, and the deaerator is a spray-type unit at 105 °C. The plant sanitises the feedwater tank weekly with a food-grade disinfectant and flushes the level electrodes, which has eliminated the false high-level trips that plagued the old boiler.
| Item | Value |
|---|---|
| Rated evaporation | 4 t/h |
| Pressure / temperature | 1.0 MPa / 184 °C |
| Average / peak load | 2.5-3.0 / 3.8 t/h |
| Boiler water TDS | 2,500 ppm |
| Steam dryness | above 0.98 |
| Fuel | natural gas |
The plant sits at the end of a medium-pressure branch, and gas pressure drops during the winter peak. The burner was therefore selected with a wider gas-train range and a pressure switch that alarms at 30 kPa rather than tripping the boiler. The plant also kept its old diesel boiler as a winter standby, and the two share a header.
Uzbekistan’s gas is slightly different from the methane basis used at the quotation stage, and the commissioning engineer trimmed the combustion curve on site with a portable analyser. CO is now under 20 ppm at all firing rates, and NOx is within the local limit.
The boiler has run through one full winter without a gas-pressure trip. Specific fuel consumption is about 78 Nm3 per tonne of steam, and the plant has not had a single carry-over complaint from the cooking line. The only recurring maintenance is the burner’s flame scanner, which is cleaned every 500 hours because of local dust.
External links open the publisher’s website and are provided for background reading.
Yes, with a separator, controlled boiler-water chemistry and stainless feedwater piping. Where steam touches product directly, many plants add a clean-steam or filtration skid.
The site is at the end of a gas branch and winter pressure dips. A standby unit protects production; it runs only a few days a year.
Above 0.98 with a properly sized steam space, a separator and blowdown control. Carry-over rises sharply if TDS is allowed above 3,000 ppm.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.