4 t/h Equivalent Thermal Oil Heater for a Chemical Plant in Tema, Ghana

A 2.8 MW gas thermal oil heater holds 300 C for a resin and coatings plant in Tema, Ghana, replacing a high-pressure steam system with a low-pressure loop.

Electromagnetic Thermal Oil Heater, 7-1400 kW – Yuanda Boiler
Place
Tema, Ghana
Industry
Chemicals
Equipment
1 x 2.8 MW gas-fired thermal oil heater
Year
2025

300 °C without high-pressure steam

The plant in Tema makes resins and industrial coatings, and several reactors need jacket temperatures of 280-300 °C. Steam at that temperature would need about 8.5 MPa, which means a water-tube boiler, a deaerator, water treatment and a licensed operator. The plant instead installed a 2.8 MW gas-fired thermal oil heater with a 300 °C supply and a 270 °C return.

The heater is a vertical coil type with a gas burner at the top and flue gas running down the outside of the coil. The loop runs at 0.6 MPa – just enough to keep the oil liquid at temperature – and the reactors are heated through their existing jackets with a modulating three-way valve.

Loop design

The circulating flow is about 110 m3/h at a 30 K drop, which gives 2.8 MW at the oil’s specific heat of about 2.6 kJ/kg·K and a density near 830 kg/m3 at 285 °C. The main pump has a standby, and a minimum-flow bypass protects the coil if the process valves close.

The expansion tank is nitrogen-blanketed to prevent oxidation, and the loop is filled through a filter. The plant warms the loop at 30 K/h, which takes about eight hours from cold to 300 °C and avoids thermal shock to the coil and the reactors.

Loop data
Item Value
Heater duty 2.8 MW
Oil supply / return 300 / 270 °C
Circulating flow about 110 m3/h
Loop pressure 0.6 MPa
Warm-up rate 30 K/h
Fuel natural gas

Oil care

The plant samples the oil every 500 hours for viscosity, flash point and insolubles. A falling flash point means light ends are forming through cracking, which happens when the film temperature at the coil wall exceeds the oil’s limit. The coil is sized for a tube velocity above 1.5 m/s at full flow, and the plant keeps the bypass open at low demand to hold that velocity.

The heater’s stack temperature is the plant’s fouling indicator. A rise of 20 K at constant duty means the coil’s gas side needs cleaning, which the plant does with a dry-ice blast during the annual shutdown.

Why the switch paid

The old steam system had a water-treatment plant, a deaerator, daily blowdown and a boiler operator on every shift. The oil loop has one pump, one heater and a expansion tank; the plant’s operators check flow, temperature and stack temperature once a shift. The heater also starts and stops with the reactors rather than staying hot all week, which cut gas use by about 18% in the first year.

Frequently asked questions

Why use thermal oil instead of 8.5 MPa steam?

A liquid-phase loop delivers 300 C at 0.6 MPa with no water treatment, no blowdown and no licensed high-pressure operation. The equipment and operating cost are far lower.

What limits the oil's life?

Film temperature at the coil wall. Keeping tube velocity above 1.5 m/s and the supply temperature within the oil's rating gives several years of service.

Can the heater follow a batch reactor load?

Yes, with a modulating burner and a three-way valve on the loop. The minimum-flow bypass keeps coil velocity up when the reactors are closed.