A paper mill steam balance is not a single number; it is a set of linked balances across the dryer section, the condensate and flash recovery system, and the hood and ventilation air. Getting them to close within a few percent is what makes a boiler sizing, heat recovery or efficiency project defensible. This article sets out a working method with representative engineering values, so you can see where the steam actually goes and where the recoverable energy sits.

Start with the dryer section demand

Drying load is driven by water evaporated, not by paper tonnage directly. A useful planning figure is the specific evaporation rate: on a modern machine, 1.3 to 1.6 kg water per kg of paper is typical at the reel, depending on grade and incoming dryness. For a machine producing 20 t/h of paper at 1.4 kg water/kg paper, evaporation is 28 t/h of water.

The steam demand follows from the latent heat and the dryer efficiency. At 4 bar(g) saturated steam, latent heat is about 2,103 kJ/kg. If the dryer section delivers roughly 3,000 to 3,400 kJ per kg of water evaporated (including losses to the hood and radiation), steam consumption is around 1.4 to 1.6 kg steam per kg water. For 28 t/h evaporation that is roughly 40 to 45 t/h of steam at the dryer inlet. Treat these as planning values and replace them with your own machine data before committing to equipment.

Section-by-section, the first dryer groups (after the press section) run cooler, often 2 to 3 bar(g), while later groups run at 5 to 8 bar(g). Splitting demand by section matters because it determines the pressure cascade and the flash potential downstream.

Condensate cascade and blow-through

Each dryer cylinder discharges condensate through a siphon and a steam trap or a cascade control arrangement. In a cascade system, the condensate from a high-pressure group is flashed into a lower-pressure group’s steam header rather than being dumped to the condensate tank. This recovers heat and reduces live steam to the low-pressure groups.

The cascade only works if the pressure difference across each stage is sufficient to drive the condensate and flash. A practical rule is a minimum 1.5 to 2 bar differential between cascade stages, and flash vessels sized for the flash fraction. The flash fraction from pressure P1 to P2 is approximately (h_f1 – h_f2) / h_fg2. For example, condensate at 6 bar(g) (saturation 165 °C, h_f ≈ 697 kJ/kg) flashed to 2 bar(g) (saturation 134 °C, h_f ≈ 561 kJ/kg, h_fg ≈ 2,163 kJ/kg) gives a flash fraction of about 6.3%.

Blow-through steam from the siphons is often 10 to 20% of cylinder steam flow and must be accounted for; it is not free steam, and excessive blow-through is a common hidden loss.

Flash steam recovery: what it is worth

Flash steam from the condensate cascade and from continuous blowdown can be returned to a low-pressure header feeding the first dryer groups or the hood air heaters. The value is the avoided live steam at that pressure. Using the example above, if 40 t/h of condensate at 6 bar(g) cascades to 2 bar(g), the flash is about 2.5 t/h of low-pressure steam. At 2 bar(g) that displaces roughly 2.5 t/h of live steam, which is a meaningful fraction of the low-pressure demand.

Flash recovery is limited by matching flash availability to low-pressure demand at the same time. If the mill has no low-pressure user, flash steam is vented and the energy is lost. This is why the balance must be time-matched, not annualised.

Hood and ventilation balance

The dryer hood is a heat and mass balance in its own right. Supply air is heated to 80 to 110 °C, passes over the web, and leaves at 75 to 95 °C with a moisture load equal to the evaporation rate plus any infiltration. A typical hood exhaust humidity is 0.08 to 0.12 kg water per kg dry air. For 28 t/h evaporation and an exhaust humidity of 0.10 kg/kg, dry air flow is about 280 t/h, or roughly 230,000 m³/h at 90 °C.

Hood supply air heating is often the largest low-pressure steam user, and it competes directly with flash steam recovery. A heat balance across the hood shows whether the air heaters are oversized, whether exhaust recirculation is possible, and how much flash steam can be absorbed.

Worked balance table

The table below is an illustrative balance for a 20 t/h machine at 1.4 kg water/kg paper. Values are planning estimates; replace with measured data.

Item Value Unit Assumption
Paper production 20 t/h Reel, steady state
Evaporation 28 t/h 1.4 kg water/kg paper
Dryer steam demand 42 t/h 1.5 kg steam/kg water, 4 bar(g)
Blow-through allowance 15 % Of cylinder steam
Condensate to cascade 40 t/h At 6 bar(g)
Flash fraction (6 to 2 bar(g)) 6.3 % h_f 697 to 561 kJ/kg
Flash steam available 2.5 t/h At 2 bar(g)
Hood exhaust air 280 t/h dry air 0.10 kg/kg humidity
Hood supply temperature 95 °C Steam air heater

Checklist before you size anything

  • Machine speed, basis weight and reel moisture for each grade.
  • Steam flow and pressure at each dryer group inlet, logged over a full grade run.
  • Condensate flow and temperature at each cascade stage and at the return tank.
  • Trap and siphon condition; blow-through steam estimated or measured.
  • Flash vessel pressures and vent rates; where flash steam is currently used or lost.
  • Hood supply and exhaust air flows, temperatures and humidity.
  • Boiler house steam output, feedwater temperature and blowdown rate.
  • Any seasonal or grade-related variation in the above.

Once these are in hand, the balance can be closed and the boiler and heat recovery options compared on the same basis. Our product range covers the boiler and flash recovery equipment, and the capacity and cost guide explains what drives sizing and cost.

What to send us for a proposal

Send the machine data sheet, a steam and condensate schematic, and 24-hour logs of steam flow, pressure, condensate temperature and hood air conditions for the representative grade. Include the existing boiler rating, feedwater temperature and any flash recovery already installed. With that, we can build the balance, identify the recoverable flash and hood savings, and propose equipment sized to your actual demand rather than a nominal figure. Cost is driven mainly by steam capacity, pressure rating, feedwater temperature, burner and controls scope, and the extent of flash and condensate recovery included.