0.1-2 t/h
Packaged Steam Generator, 0.1-2 t/h
Multi-pass packaged steam generator, 0.1-2 t/h at 0.4-0.7 MPa, small water content and fast start for pressing, food and sterilizi...
View detailsThe SZS35-1.6-Q is a 35 t/h D-type double-drum water-tube boiler delivering 1.6 MPa steam at 204°C. It fires natural gas, LPG, light diesel or heavy fuel oil at 95% efficiency (LHV) and suits high-capacity industrial steam demand.

The SZS35-1.6-Q is a member of the SZS series of D-type double-drum water-tube steam boilers. Rated at 35 t/h, it produces steam at 1.6 MPa and 204 °C. The membrane-wall furnace and two-drum configuration are engineered for high-capacity service, offering reliable performance with a range of liquid and gaseous fuels.
At 35 t/h, this boiler is well matched to large industrial processes that require a continuous, high-volume steam supply. Typical applications include large-scale chemical and petrochemical plants, refineries, pulp and paper mills, and central heating plants for industrial parks or district energy systems. The capacity supports processes where steam demand is steady and substantial, and where a single boiler can serve as the primary steam source.
The SZS35-1.6-Q is designed to fire natural gas, LPG, light diesel, or heavy fuel oil. The fuel consumption at rated output is 2601 Nm³/h when fired with natural gas at 95% efficiency (LHV basis). This figure is derived from the rated steam output, the enthalpy rise from feedwater to steam, and the lower heating value of the fuel, divided by the boiler efficiency. For other fuels, consumption will vary according to their respective heating values and combustion characteristics.
At this size, the boiler exhibits stable part-load operation. The D-type water-tube design and membrane-wall construction provide good circulation and temperature distribution across the load range. The burner and control system are selected to maintain efficient combustion at reduced loads, though efficiency will typically decline as load decreases. For optimal fuel economy, the boiler is best operated between 60% and 100% of rated capacity.
The SZS35-1.6-Q is a shop-assembled, D-type boiler with a compact footprint relative to its capacity. Installation requires a suitable foundation, adequate space for burner maintenance and tube access, and proper clearances for piping, ductwork, and ancillary equipment. The membrane-wall construction reduces the need for extensive refractory, simplifying site erection. General arrangement drawings should be consulted for detailed space planning.
Proper water treatment is essential for reliable operation and longevity. Feedwater should be softened and deaerated to minimize scale and corrosion. The boiler water chemistry must be controlled within the limits specified in the operating manual to prevent carryover and deposition. A continuous blowdown system is recommended to manage dissolved solids.
The boiler is supplied with a combustion control system that modulates the burner to match steam demand. Safety interlocks monitor water level, steam pressure, and flame presence, ensuring safe shutdown if abnormal conditions occur. The control panel can be integrated with plant-wide monitoring systems for remote supervision.
Choosing the 35 t/h model balances capacity and efficiency for plants with high steam demand. It avoids the higher capital cost and larger footprint of the next size up while providing more capacity than smaller units, reducing the number of boilers needed. This makes it a cost-effective solution for facilities requiring a single, robust steam source.
| Model | SZS35-1.6-Q |
|---|---|
| Capacity | 35 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | 104 °C |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 2601 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with combustion control system |
| Application | Large industrial processes, chemical, petrochemical, pulp & paper, district heating |
The boiler is rated at 35 tonnes of steam per hour (t/h) at a pressure of 1.6 MPa and a temperature of 204 °C.
It can fire natural gas, LPG, light diesel, or heavy fuel oil. When using natural gas at rated output and 95% efficiency (LHV), fuel consumption is 2601 Nm³/h.
The boiler achieves 95% efficiency on a lower heating value (LHV) basis when operating at rated conditions with natural gas.
| Model | SZS35-1.6-Q |
|---|---|
| Capacity | 35 t/h |
| Pressure | 1.6 MPa |
| Steam temperature | 204 °C |
| Feedwater temperature | 104 °C |
| Fuel | Natural gas, LPG, light diesel, heavy fuel oil |
| Fuel consumption at rated output | 2601 Nm³/h (natural gas, 95% efficiency) |
| Efficiency | 95% (LHV basis) |
| Burner/control | Modulating burner with combustion control system |
| Application | Large industrial processes, chemical, petrochemical, pulp & paper, district heating |
External links open the publisher’s website and are provided for background reading.
Include the capacity (t/h or MW), fuel, working pressure and site country so the proposal matches your permit limits.
We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.