Capacity & Cost guide Industrial boiler manufacturer since 1965 Taikang, Zhoukou, Henan, China

20 t/h · steam boiler

20 tonne steam boiler: output, fuel bill and price band

Twenty tonnes per hour produces 20,000 kg/h of steam, about 14 MW. It is a utility-scale package: two-drum or D-type water-tube, forced or balanced draft, and a control system that talks to the plant DCS rather than standing alone.

20 t/h20 × 1,000 kg steam per hour
14.00 MWthermal output
$136k–$202kgas package, indicative

Water-tube boiler with a chain grate stoker
Water-tube boiler with a chain grate stoker Factory render

Where this size fits

At this size the boiler house layout is designed first and the boiler selected to fit it. Flue routing, fuel train, deaerator elevation and maintenance access determine more of the final cost than the choice between two comparable shells.

For continuous plants with a base load of 14–18 t/h. Below 10 t/h average, the unit will cycle and the efficiency advantage disappears; consider 12 or 15 t/h instead.

Pressure vessel shell on turning rolls in the assembly hall
Pressure vessel shell on turning rolls in the assembly hall
Control panel inspection before factory testing
Control panel inspection before factory testing

Load profile check

One shift

8 h/day at 80% load delivers about 128,000 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.

Two shifts

16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.

Continuous

24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.

Machines at this output

SZS20-1.25-Y(Q)

Gas / oil, D-type water-tube

Pressure
1.25 MPa
Steam temp.
194 °C
Efficiency
94–96%
Indicative
$136k–202k

SZL20-1.25-T

Biomass, assembled water-tube

Pressure
1.25 MPa
Steam temp.
194 °C
Efficiency
87–89%
Indicative
$175k–245k

SZS20-2.5-Y(Q)

Gas / oil, 2.5 MPa

Pressure
2.5 MPa
Steam temp.
226 °C
Efficiency
94–96%
Indicative
$152k–222k

Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.

What a tonne of steam costs

Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.

Natural gas

$35.29 per tonne · 1,535 Nm³/h · $706/h at full load

Light diesel

$62.09 per tonne · 1,307 kg/h · $1,242/h at full load

Biomass pellet

$27.91 per tonne · 3,488 kg/h · $558/h at full load

Bituminous coal

$19.02 per tonne · 2,927 kg/h · $380/h at full load

At eight hours a day and 300 days a year, the gas line alone is about $1,694,118 a year at full fire. Electricity, water, labour and maintenance are excluded.

Market price map

Equipment only

$136k–$202k

Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.

Packaged skid

$184k–$303k

Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.

Turnkey

+35–60%

Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.

Twenty-tonne projects are usually tendered with a performance guarantee: efficiency at a stated load, stack temperature, NOx at a stated O₂, and steam quality. Make those numbers part of the contract, not the brochure.

Typical duties

  • Sugar mills and refineries
  • Chemical and petrochemical utilities
  • Large textile complexes
  • District heating primary plants

Ask for the guaranteed efficiency at 50%, 75% and 100% load — a single full-load figure hides part-load behaviour.

Questions buyers ask at this size

What does a 20 t/h steam boiler cost?

Indicative 2026 EXW range: $136k–$202k for a gas/oil packaged unit, $175k–$245k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.

How much gas does a 20 t/h boiler burn per hour?

About 1,535 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $706 per hour at 0.46 USD/Nm³.

Can a 20 t/h boiler follow a load that swings by 8 t/h?

Yes with a modulating burner and a properly sized drum, but the steam header and control valves must be able to absorb the swing too. If the swing is faster than two minutes, a steam accumulator is the usual fix.

What is 20 t/h in MW and kcal per hour?

20 t/h is about 14.00 MW, 12,000,000 kcal/h, or roughly 1,280 boiler horsepower.

Sources and further reading

Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.

Request a quote

Tell us the capacity, fuel and working pressure. Our engineers reply with a technical proposal within one working day.

Or email [email protected] directly.

Partners

Become a Yuanda Boiler agent

We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.

Apply as an agent
WhatsApp [email protected]
Call WhatsApp Email Get a quote