0.5 t/h · steam boiler
0.5 tonne steam boiler: output, fuel bill and price band
Half a tonne per hour is 500 kg of steam an hour — 0.35 MW, or 300,000 kcal/h. Below this output the packaged horizontal shell stops making sense and the market splits into vertical once-through units, small electric boilers and integrated steam generators that arrive on a skid with the feedwater pump already wired.

Where this size fits
What decides the choice at 0.5 t/h is not efficiency, it is the shape of the demand. A laundry that fires for six hours and stops wants a small fire-tube with a buffer; a laboratory that draws 80 kg/h for twenty minutes at a time wants an electric generator that responds instantly and costs nothing when idle.
Right for a peak between 300 and 450 kg/h with long idle periods. If the peak is already 0.6 t/h, step to the 1 t/h page: running a 0.5 t/h unit flat out every morning is how small boilers die early.


Load profile check
One shift
8 h/day at 80% load delivers about 3,200 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.
Two shifts
16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.
Continuous
24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.
Machines at this output
LSS0.5-1.0-Y(Q)
Vertical gas/oil, once-through
- Pressure
- 1.0 MPa
- Steam temp.
- 184 °C
- Efficiency
- 91–93%
- Indicative
- $6k–10k
WNS0.5-1.0-Y(Q)
Horizontal 3-pass, packaged
- Pressure
- 1.0 MPa
- Steam temp.
- 184 °C
- Efficiency
- 90–92%
- Indicative
- $8k–12k
LDR0.5-0.7-D
Vertical electric, 350 kW
- Pressure
- 0.7 MPa
- Steam temp.
- 170 °C
- Efficiency
- 98%
- Indicative
- $5k–8k
Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.
What a tonne of steam costs
Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.
Natural gas
$35.29 per tonne · 38 Nm³/h · $18/h at full load
Light diesel
$62.09 per tonne · 33 kg/h · $31/h at full load
Biomass pellet
$27.91 per tonne · 87 kg/h · $14/h at full load
Bituminous coal
$19.02 per tonne · 73 kg/h · $10/h at full load
At eight hours a day and 300 days a year, the gas line alone is about $42,353 a year at full fire. Electricity, water, labour and maintenance are excluded.
Market price map
Equipment only
$6k–$10k
Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.
Packaged skid
$8k–$15k
Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.
Turnkey
+35–60%
Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.
This band is the least standardised in the whole range. Vertical imports, domestic copies, electric generators and converted hot-water units all compete, and the price spread between them reflects control package and certification rather than steel. Ask for the pressure vessel certificate and the burner test sheet separately — at this size they are frequently the two weakest documents in the file.
Typical duties
- Commercial laundries and dry cleaners
- Central kitchens and food stalls
- Clinics and sterilisation rooms
- Concrete block and panel curing
At 0.5 t/h, standby loss is a real share of the fuel bill. Insulation quality and a proper condensate return matter more here than the burner turndown ratio.
Keep reading
Nearby sizes: 1 t/h boiler
Machines in this range
Closest reference projects
Questions buyers ask at this size
What does a 0.5 t/h steam boiler cost?
Indicative 2026 EXW range: $6k–$10k for a gas/oil packaged unit, $9k–$14k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.
How much gas does a 0.5 t/h boiler burn per hour?
About 38 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $18 per hour at 0.46 USD/Nm³.
Can a 0.5 t/h boiler run a laundry?
A single ironer plus two washer-extractors typically draws 250–400 kg/h. A 0.5 t/h unit covers that, but only if the ironer and the washers are not started together from cold. Stagger the morning start by twenty minutes, or fit a 1,000-litre buffer tank.
What is 0.5 t/h in MW and kcal per hour?
0.5 t/h is about 0.35 MW, 300,000 kcal/h, or roughly 32 boiler horsepower.
Sources and further reading
- Spirax Sarco — steam engineering tutorials: steam tables, enthalpy and blowdown practice.
- U.S. Department of Energy — steam systems: load profiling and steam-system efficiency measures.
- ASME Boiler and Pressure Vessel Code, Section I: the construction standard referenced by many export projects.
Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.