20 t/h · steam boiler
20 tonne steam boiler: output, fuel bill and price band
Twenty tonnes per hour produces 20,000 kg/h of steam, about 14 MW. It is a utility-scale package: two-drum or D-type water-tube, forced or balanced draft, and a control system that talks to the plant DCS rather than standing alone.

Where this size fits
At this size the boiler house layout is designed first and the boiler selected to fit it. Flue routing, fuel train, deaerator elevation and maintenance access determine more of the final cost than the choice between two comparable shells.
For continuous plants with a base load of 14–18 t/h. Below 10 t/h average, the unit will cycle and the efficiency advantage disappears; consider 12 or 15 t/h instead.


Load profile check
One shift
8 h/day at 80% load delivers about 128,000 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.
Two shifts
16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.
Continuous
24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.
Machines at this output
SZS20-1.25-Y(Q)
Gas / oil, D-type water-tube
- Pressure
- 1.25 MPa
- Steam temp.
- 194 °C
- Efficiency
- 94–96%
- Indicative
- $136k–202k
SZL20-1.25-T
Biomass, assembled water-tube
- Pressure
- 1.25 MPa
- Steam temp.
- 194 °C
- Efficiency
- 87–89%
- Indicative
- $175k–245k
SZS20-2.5-Y(Q)
Gas / oil, 2.5 MPa
- Pressure
- 2.5 MPa
- Steam temp.
- 226 °C
- Efficiency
- 94–96%
- Indicative
- $152k–222k
Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.
What a tonne of steam costs
Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.
Natural gas
$35.29 per tonne · 1,535 Nm³/h · $706/h at full load
Light diesel
$62.09 per tonne · 1,307 kg/h · $1,242/h at full load
Biomass pellet
$27.91 per tonne · 3,488 kg/h · $558/h at full load
Bituminous coal
$19.02 per tonne · 2,927 kg/h · $380/h at full load
At eight hours a day and 300 days a year, the gas line alone is about $1,694,118 a year at full fire. Electricity, water, labour and maintenance are excluded.
Market price map
Equipment only
$136k–$202k
Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.
Packaged skid
$184k–$303k
Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.
Turnkey
+35–60%
Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.
Twenty-tonne projects are usually tendered with a performance guarantee: efficiency at a stated load, stack temperature, NOx at a stated O₂, and steam quality. Make those numbers part of the contract, not the brochure.
Typical duties
- Sugar mills and refineries
- Chemical and petrochemical utilities
- Large textile complexes
- District heating primary plants
Ask for the guaranteed efficiency at 50%, 75% and 100% load — a single full-load figure hides part-load behaviour.
Keep reading
Nearby sizes: 15 t/h boiler25 t/h boiler
Machines in this range
Closest reference projects
Questions buyers ask at this size
What does a 20 t/h steam boiler cost?
Indicative 2026 EXW range: $136k–$202k for a gas/oil packaged unit, $175k–$245k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.
How much gas does a 20 t/h boiler burn per hour?
About 1,535 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $706 per hour at 0.46 USD/Nm³.
Can a 20 t/h boiler follow a load that swings by 8 t/h?
Yes with a modulating burner and a properly sized drum, but the steam header and control valves must be able to absorb the swing too. If the swing is faster than two minutes, a steam accumulator is the usual fix.
What is 20 t/h in MW and kcal per hour?
20 t/h is about 14.00 MW, 12,000,000 kcal/h, or roughly 1,280 boiler horsepower.
Sources and further reading
- Spirax Sarco — steam engineering tutorials: steam tables, enthalpy and blowdown practice.
- U.S. Department of Energy — steam systems: load profiling and steam-system efficiency measures.
- ASME Boiler and Pressure Vessel Code, Section I: the construction standard referenced by many export projects.
Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.