30 t/h · steam boiler
30 tonne steam boiler: output, fuel bill and price band
Thirty tonnes per hour, about 21 MW, sits at the top of the packaged water-tube range before designs move to field-erected utility boilers. Most units at this size are D-type with a single drum and membrane walls, shipped in modules that fit standard flat-rack or open-top containers.

Where this size fits
Fuel flexibility becomes a commercial question here. A dual-fuel burner that runs gas normally and oil during curtailment costs more upfront but is often the difference between stopping production and continuing through a supply interruption.
Appropriate for a site with 20–26 t/h continuous demand and a steam network with several users. Below that, part-load operation erodes the efficiency gain over a 20 t/h unit.


Load profile check
One shift
8 h/day at 80% load delivers about 192,000 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.
Two shifts
16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.
Continuous
24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.
Machines at this output
SZS30-1.6-Y(Q)
Gas / oil, D-type water-tube
- Pressure
- 1.6 MPa
- Steam temp.
- 204 °C
- Efficiency
- 94–96%
- Indicative
- $198k–292k
SZS30-2.5-Y(Q)
Gas / oil, 2.5 MPa
- Pressure
- 2.5 MPa
- Steam temp.
- 226 °C
- Efficiency
- 94–96%
- Indicative
- $218k–318k
SZL30-1.6-T
Biomass, water-tube
- Pressure
- 1.6 MPa
- Steam temp.
- 204 °C
- Efficiency
- 87–89%
- Indicative
- $240k–335k
Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.
What a tonne of steam costs
Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.
Natural gas
$35.29 per tonne · 2,302 Nm³/h · $1,059/h at full load
Light diesel
$62.09 per tonne · 1,961 kg/h · $1,863/h at full load
Biomass pellet
$27.91 per tonne · 5,233 kg/h · $837/h at full load
Bituminous coal
$19.02 per tonne · 4,390 kg/h · $571/h at full load
At eight hours a day and 300 days a year, the gas line alone is about $2,541,176 a year at full fire. Electricity, water, labour and maintenance are excluded.
Market price map
Equipment only
$198k–$292k
Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.
Packaged skid
$267k–$438k
Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.
Turnkey
+35–60%
Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.
Thirty-tonne pricing is dominated by the balance of plant: feedwater treatment, deaerator, economiser, stack, burner controls and erection can add 40–60% to the vessel price. Budget the whole system before comparing suppliers.
Typical duties
- Chemical complexes
- Large beverage plants
- Board and packaging mills
- District energy schemes
Dual-fuel capability needs a fuel train, changeover logic and a permit review; it is not a burner-only upgrade.
Keep reading
Nearby sizes: 25 t/h boiler40 t/h boiler
Machines in this range
Closest reference projects
Questions buyers ask at this size
What does a 30 t/h steam boiler cost?
Indicative 2026 EXW range: $198k–$292k for a gas/oil packaged unit, $240k–$335k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.
How much gas does a 30 t/h boiler burn per hour?
About 2,302 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $1,059 per hour at 0.46 USD/Nm³.
Is dual fuel worth it at 30 t/h?
Only if a gas interruption would stop production. The premium is roughly 8–12% of the burner and fuel-train cost, plus permitting. Where gas supply is firm, the money is better spent on heat recovery.
What is 30 t/h in MW and kcal per hour?
30 t/h is about 21.00 MW, 18,000,000 kcal/h, or roughly 1,920 boiler horsepower.
Sources and further reading
- Spirax Sarco — steam engineering tutorials: steam tables, enthalpy and blowdown practice.
- U.S. Department of Energy — steam systems: load profiling and steam-system efficiency measures.
- ASME Boiler and Pressure Vessel Code, Section I: the construction standard referenced by many export projects.
Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.