10 t/h · steam boiler
10 tonne steam boiler: output, fuel bill and price band
Ten tonnes per hour — 10,000 kg/h, about 7 MW — is the entry point to utility-style operation. The unit is normally water-tube, delivered in sections, and the plant around it now includes a deaerator, a blowdown vessel, dosing and a control system that reports to a plant DCS.

Where this size fits
This is also where the economics of heat recovery become explicit. An economiser plus, on gas, a condensing unit can move overall efficiency by five to eight points; at 10 t/h and 6,000 hours a year that is worth more than the difference between two competitive boiler bids.
For a plant with a 7–9 t/h continuous demand. Below a 6 t/h average, a 6 or 8 t/h unit plus a standby is usually the cheaper arrangement to operate.


Load profile check
One shift
8 h/day at 80% load delivers about 64,000 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.
Two shifts
16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.
Continuous
24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.
Machines at this output
SZS10-1.25-Y(Q)
Gas/oil, D-type water-tube
- Pressure
- 1.25 MPa
- Steam temp.
- 194 °C
- Efficiency
- 94–96%
- Indicative
- $67k–102k
WNS10-1.25-Y(Q)
Gas/oil, large packaged fire-tube
- Pressure
- 1.25 MPa
- Steam temp.
- 194 °C
- Efficiency
- 94–96%
- Indicative
- $72k–108k
SZL10-1.25-T
Biomass, assembled water-tube
- Pressure
- 1.25 MPa
- Steam temp.
- 194 °C
- Efficiency
- 87–89%
- Indicative
- $96k–138k
Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.
What a tonne of steam costs
Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.
Natural gas
$35.29 per tonne · 767 Nm³/h · $353/h at full load
Light diesel
$62.09 per tonne · 654 kg/h · $621/h at full load
Biomass pellet
$27.91 per tonne · 1,744 kg/h · $279/h at full load
Bituminous coal
$19.02 per tonne · 1,463 kg/h · $190/h at full load
At eight hours a day and 300 days a year, the gas line alone is about $847,059 a year at full fire. Electricity, water, labour and maintenance are excluded.
Market price map
Equipment only
$67k–$102k
Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.
Packaged skid
$90k–$153k
Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.
Turnkey
+35–60%
Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.
Ten-tonne projects are tendered rather than shopped. Expect separate scope for boiler, burner, BOP, civil, erection and commissioning, and a performance test at 100% and 75% load. Make the efficiency and emission guarantees contractual, with the test method written in.
Typical duties
- Sugar mills
- District heating plants
- Chemical utilities
- Large food and beverage sites
Confirm the local emission limit and the reference oxygen level before the burner is fixed. Retrofitting low-NOx capability later costs several times the specification difference.
Keep reading
Nearby sizes: 8 t/h boiler12 t/h boiler
Machines in this range
Closest reference projects
Questions buyers ask at this size
What does a 10 t/h steam boiler cost?
Indicative 2026 EXW range: $67k–$102k for a gas/oil packaged unit, $96k–$138k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.
How much gas does a 10 t/h boiler burn per hour?
About 767 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $353 per hour at 0.46 USD/Nm³.
What does a 10 t/h boiler cost to run?
At full fire on gas: about 767 Nm³/h, roughly 353 USD an hour at 0.46 USD/Nm³, assuming 8,500 kcal/Nm³ and 92% efficiency. Over 6,000 hours that is over 2 million USD a year, which is why a one-point efficiency gain is worth chasing at this size.
What is 10 t/h in MW and kcal per hour?
10 t/h is about 7.00 MW, 6,000,000 kcal/h, or roughly 640 boiler horsepower.
Sources and further reading
- Spirax Sarco — steam engineering tutorials: steam tables, enthalpy and blowdown practice.
- U.S. Department of Energy — steam systems: load profiling and steam-system efficiency measures.
- ASME Boiler and Pressure Vessel Code, Section I: the construction standard referenced by many export projects.
Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.