Capacity & Cost guide Industrial boiler manufacturer since 1965 Taikang, Zhoukou, Henan, China

1 t/h · steam boiler

1 tonne steam boiler: output, fuel bill and price band

One tonne per hour — 1,000 kg/h, 0.7 MW, 600,000 kcal/h — is the most common first industrial boiler in the world. It ships as a single packaged unit, fits in a 20-foot container, and needs nothing more than a foundation, a flue and a softener to run.

1 t/h1 × 1,000 kg steam per hour
0.70 MWthermal output
$9k–$15kgas package, indicative

Packaged fire-tube boiler with a pressure-jet burner
Packaged fire-tube boiler with a pressure-jet burner Factory render

Where this size fits

The engineering decision at 1 t/h is pressure. Most units are quoted at 1.0 MPa, which caps the steam temperature at 184 °C. If any user in the plant needs 1.25 MPa — many dryers, most CIP sets — specify it now: the price step is small, and a shell cannot be re-rated later.

The right size where the peak sits at 0.7–0.9 t/h and the plant runs one or two shifts. If the peak touches 1 t/h regularly, take the 2 t/h page instead — headroom is cheaper than a rebuild.

WNS fire-tube boiler with the furnace and tube bundle shown
WNS fire-tube boiler with the furnace and tube bundle shown
Welding bay with boiler shells and drum sections
Welding bay with boiler shells and drum sections

Load profile check

One shift

8 h/day at 80% load delivers about 6,400 kg of steam a day. Steam demand is concentrated; the boiler starts cold each morning.

Two shifts

16 h/day at 75% average is the usual sweet spot for this size: the unit stays in modulation and avoids a second cold start.

Continuous

24 h at 70–85% load is where the efficiency figures in this page actually hold. Below 50% load, expect the fuel cost per tonne to rise.

Machines at this output

WNS1-1.25-Y(Q)

Gas/oil, 3-pass wet-back

Pressure
1.25 MPa
Steam temp.
194 °C
Efficiency
92–94%
Indicative
$9k–15k

LSS1-1.0-Y(Q)

Vertical gas/oil, compact footprint

Pressure
1.0 MPa
Steam temp.
184 °C
Efficiency
91–93%
Indicative
$8k–13k

DZL1-1.25-T

Biomass/coal, small chain grate

Pressure
1.25 MPa
Steam temp.
194 °C
Efficiency
84–86%
Indicative
$15k–22k

Efficiency ranges assume LHV basis and a clean unit at rated load. Local emission limits may require a low-NOx burner and, on gas, flue-gas recirculation.

What a tonne of steam costs

Basis: 600,000 kcal per tonne of steam at 1.25 MPa with 68 °C feedwater; gas 8,500 kcal/Nm³ at 0.46 USD/Nm³; diesel 10,200 kcal/kg at 0.95 USD/kg; biomass 4,000 kcal/kg at 0.16 USD/kg; coal 5,000 kcal/kg at 0.13 USD/kg. Efficiency 92% gas, 90% diesel, 86% biomass, 82% coal.

Natural gas

$35.29 per tonne · 77 Nm³/h · $35/h at full load

Light diesel

$62.09 per tonne · 65 kg/h · $62/h at full load

Biomass pellet

$27.91 per tonne · 174 kg/h · $28/h at full load

Bituminous coal

$19.02 per tonne · 146 kg/h · $19/h at full load

At eight hours a day and 300 days a year, the gas line alone is about $84,706 a year at full fire. Electricity, water, labour and maintenance are excluded.

Market price map

Equipment only

$9k–$15k

Boiler body, burner, control panel. Excludes feedwater, economiser, water treatment, flue and erection.

Packaged skid

$12k–$23k

Adds feedwater pump set, softener, economiser and the interconnecting pipework on a common frame.

Turnkey

+35–60%

Adds foundation, flue and stack, electrical, insulation, erection, commissioning and performance test.

At 1 t/h, freight and certification are a larger share of the delivered price than at any other size. A CE-marked unit and an unmarked one can differ by 30% with the same pressure part; the difference is documentation, not steel. Ask which standard the vessel is designed to before comparing.

Typical duties

  • Small dairies and juice lines
  • Laundries with ironers
  • Feed mills and pellet lines
  • Greenhouses and soil sterilisation

In several jurisdictions a steam boiler at or below 1 t/h and 1.0 MPa falls under a lighter inspection regime. Confirm with the local authority before fixing the pressure — it can change both the price and the commissioning timeline.

Questions buyers ask at this size

What does a 1 t/h steam boiler cost?

Indicative 2026 EXW range: $9k–$15k for a gas/oil packaged unit, $15k–$22k for a biomass chain-grate unit. Pressure, burner class, economiser and auxiliary scope move the figure by 20–40%.

How much gas does a 1 t/h boiler burn per hour?

About 77 Nm³/h at full load, assuming 8,500 kcal/Nm³ and 92% thermal efficiency. That is roughly $35 per hour at 0.46 USD/Nm³.

Gas or electric for a 1 t/h boiler?

Electric at 1 t/h means roughly 700 kWh at full fire. At 0.10 USD/kWh that is 70 USD an hour, against about 35 USD for gas at 0.46 USD/Nm³. Electric wins where power is cheap, where there is no flue route, or where the boiler runs a few hours a week and standby loss dominates.

What is 1 t/h in MW and kcal per hour?

1 t/h is about 0.70 MW, 600,000 kcal/h, or roughly 64 boiler horsepower.

Sources and further reading

Fuel prices and efficiencies are stated assumptions for comparison, not quotations. Local fuel quality, altitude, feedwater temperature and part-load operation all shift the real number.

Request a quote

Tell us the capacity, fuel and working pressure. Our engineers reply with a technical proposal within one working day.

Or email [email protected] directly.

Partners

Become a Yuanda Boiler agent

We appoint one or two partners per country to quote, deliver and service our boilers locally. Territory protection, factory pricing and commissioning support are part of the agreement.

Apply as an agent
WhatsApp [email protected]
Call WhatsApp Email Get a quote