Meeting the NOx limit without losing turn-down
4 t/h at 1.0 MPa is the working point for a food plant in Izmir, Turkey, where the plant is inside a residential district with a 30 mg limit. The unit was selected on that operating pattern rather than on a catalogue rating, and the difference shows in how it holds pressure on the worst shift of the week.
Nitrogen oxides form where flame temperature and oxygen meet, so every low-NOx strategy is a way of cooling the flame or starving it locally. Staged air, flue-gas recirculation, a larger furnace and a well-matched burner can take a gas boiler from 150 mg/Nm3 to below 30 mg/Nm3 at 3% oxygen. The limit is always quoted at a reference oxygen level, and comparing figures at different references is the commonest mistake in tender evaluation.
Numbers that decide the design
At 4 t/h and 1.0 MPa the unit absorbs about 2.9 MW. On natural gas at roughly 94% efficiency, full-load demand is about 310 Nm3/h. The figures are stated at the site’s conditions, because ambient temperature, altitude and fuel analysis all move them.
| Item | Value |
|---|---|
| Rated output | 4 t/h |
| Pressure / temperature | 1.0 MPa |
| Fuel | natural gas |
| Full-load fuel demand | 310 Nm3/h |
| Thermal efficiency | about 94% |
What to watch on site
Low-NOx burners usually give up some turn-down and some flame stability at low fire. On a plant that runs at 20% load for weeks, the burner may need a smaller nozzle or a second, smaller unit. Compliance is verified with a portable analyser at several firing rates, and the record of those tests is what an inspector asks for.
Site note: the plant is inside a residential district with a 30 mg limit. The operators log header pressure and stack temperature every two hours, which is enough to see fouling and load drift before either becomes a shutdown.
Why it matters
Meeting the NOx limit without losing turn-down is not a detail to settle after the order. It decides the shell size, the burner, the feedwater train and the maintenance calendar, and it is cheaper to get right in the specification than in the boiler house.
Equipment used in this kind of plant: wns gas steam boiler and economizer. The industry side is covered in this solution page, and project cases show comparable installations.
Background reading: external reference on steam and process heat.
Questions plant engineers ask
What does mg/Nm3 at 3% O2 mean?
It is a concentration normalised to a fixed excess-air level. A figure quoted at 3% oxygen cannot be compared directly with one at 5% without recalculation.
Does flue-gas recirculation reduce efficiency?
It costs a little fan power and can add 0.5-1% fuel, but it is often the cheapest route to a 30 mg/Nm3 limit on an existing boiler.